Results 101 to 110 of about 6,574,604 (231)

Advances in Bio‐Integrated Edge Computing Systems for Smart and Connected Health

open access: yesAdvanced Materials, EarlyView.
This review explores advances in bio‐integrated edge computing for healthcare, focusing on co‐designing computing, sensing, and energy strategies to overcome integration and power challenges for optimized, decentralized operation. ABSTRACT Recent advances in bio‐integrated healthcare technologies have enabled continuous, high‐resolution monitoring and ...
Gyuwon Kim   +4 more
wiley   +1 more source

A Simple Descriptor for Solid‐State Ionic Conductors Across Chemistries

open access: yesAdvanced Materials, EarlyView.
Researchers develop a simple and transferable descriptor, distance contraction, for solid‐state ion migration across Li‐, Na‐, K‐, and Mg‐ion conductors and diverse anion chemistries. By capturing the maximum local contraction experienced by the migrating ion, the descriptor enables rapid materials screening and unifies diverse ion‐transport mechanisms.
Ramanuja Srinivasan Saravanan   +4 more
wiley   +1 more source

Quantification of Magnetic Interactions in van der Waals Heterostructures Using Lorentz Transmission Electron Microscopy and Off‐Axis Electron Holography

open access: yesAdvanced Materials, EarlyView.
Cross‐sectional Lorentz TEM and off‐axis electron holography visualize the magnetic domain structure and quantify interlayer coupling in Fe3GeTe2/graphite/Fe3GeTe2 heterostructures. A stray‐field coupling length of 37±$\pm$7 nm marks the onset of domain misalignment between the layers.
Joachim Dahl Thomsen   +6 more
wiley   +1 more source

A Retinal Matrix Stiffening Model Reveals FAK‐Dependent Mechanotransduction in Pericytes Underlies Vascular Destabilization

open access: yesAdvanced Materials, EarlyView.
In this study, we show that retinal matrix stiffness is increased in diabetic mice. Using engineered human vascular models with controlled matrix stiffness, we demonstrate that stiffening activates focal adhesion kinase (FAK) signaling in pericytes, suppresses Notch signaling, and disrupts vascular morphology.
Emily Warren   +6 more
wiley   +1 more source

Multilevel 24-Sided Polygonal Voltage-Space-Vector Structure Generation for an IM Drive Using a Single DC Source

open access: yes, 2019
Conventional two-level as well as multilevel voltage-source-inverter topologies with a hexagonal voltage-space vector structure generate low-order harmonics in the machine terminal voltages when operated beyond the linear modulation range in variable ...
Yadav, Apurv Kumar   +11 more
core   +1 more source

Spontaneous Nanopatterning and Strain Relaxation in SiGe Layers Grown by Oxidative Solid‐Phase Epitaxy

open access: yesAdvanced Materials Interfaces, EarlyView.
Thin SiGe buffer layers are grown by oxidative solid‐phase epitaxy, resulting in a nanopatterning of varying Ge concentration across the surface of the sample. The nanopatterning is caused by a hexagonal network of dislocations on the SiGe/Si(111) interface, and is visible by scanning electron microscopy, providing a non‐destructive method for ...
Sophie E. Bierer   +7 more
wiley   +1 more source

Programmable Crack Networks for Wide‐Range and Reversible Strain Sensing in Vertically Oriented van der Waals Molybdenum Disulfide Thin Films

open access: yesAdvanced Materials Technologies, EarlyView.
Vertically oriented van der Waals MoS2 thin films enable a mechanically programmable crack network for strain sensing. The initial mechanical programming protocol establishes a programmed crack configuration along weak interlayer and interdomain interfaces.
Yinli Wang, Hiroyuki Hirakata
wiley   +1 more source

Space charge measurement and analysis in low density polyethylene films

open access: yes, 2009
The growing requirement of reliability for an insulation system gives researchers greater responsibility to investigate new techniques for monitoring and diagnosing dielectrics subjected to an electric field.
Xu, Zhiqiang
core   +1 more source

Customizable Piezo‐Transmittance‐Based Multiaxial Force Sensor With Deep‐Learning‐Assisted Sensing

open access: yesAdvanced Materials Technologies, EarlyView.
Development of a soft tri‐axis piezo‐transmittance sensor with integrated LEDs and photodiodes enables multidirectional force sensing through deformation‐induced optical modulation. A tailored 1D convolutional neural network provides real‐time force direction and intensity prediction, achieving 99.6% classification accuracy and a mean squared error of ...
Filippo Peruzzi   +6 more
wiley   +1 more source

High‐Density Magnetomyography With Optical Magnetometers Reveals Spatiotemporal Patterns of Evoked Muscle Activity

open access: yesAdvanced Materials Technologies, EarlyView.
Optically pumped magnetometers are employed to contactlessly map the spatiotemporal dynamics of the magnetic field linked to electrical activity of a skeletal muscle in vivo. It is demonstrated that localization of the clinically relevant innervation zone is feasible using this non‐invasive magnetic measurement modality. ABSTRACT Magnetomyography (MMG)
Simon Nordenström   +12 more
wiley   +1 more source

Home - About - Disclaimer - Privacy