Results 11 to 20 of about 1,888 (168)
SIL Implementation on Safety Functions in Mass Transit System [PDF]
The concept of Safety Integrity Level (SIL) has been developed within different systems of standards (IEC 61508, EN50129 and DEF-STAN 00-56). These standards are applied in different areas: control technology (IEC 61508), railway technology (EN50128 and ...
James Li
doaj +1 more source
Calculation of the Dangerous Failure Rate of the Safety Function
Each safety-related function must be implemented with a defined safety integrity level (SIL) if the control system implements safety-related functions (SFs) in addition to the standard control functions. The required SIL of the SF depends on the quantity
Karol Rástočný +3 more
doaj +1 more source
Safety of Control Systems with Dual Architecture Based on PLCs
The implementation of safety functions, in contrast to ordinary control functions, requires a different approach to the design of the hardware and software of the control system.
Milan Medvedík +4 more
doaj +1 more source
HAZARD AND RISK ANALYSIS OF RAILWAY VEHICLE CONTROL SYSTEMS ACCORDING TO SAFETY INTEGRITY LEVELS [PDF]
This article presents an approach to the verification of the safety integrity level (SIL) of rail vehicle subassemblies in accordance with the applicable railway standards PN-EN ISO 50126-1, PN-EN ISO 50126:2, and PN-EN ISO 50129.
Grzegorz KACZOR +2 more
doaj +1 more source
Collision Risk Evaluation and Verification of GNSS-Based Train Integrity Detection
To meet the demand for middle and low-density railway lines, a Global Navigation Satellite System (GNSS) based on a train integrity monitoring system (TIMS) is used for train integrity detection.
Kewei Ji +4 more
doaj +1 more source
Safety Integrity Level of Shut-Off Valve in a Burner Management System [PDF]
The safety control and command system, such as the burner manage-ment system, requires that the system must be reliable, available and safe. The reliability is based on choosing equipment, with a high level of safety and which is suitable for the safety ...
Bsiss Mohammed +2 more
doaj +1 more source
SIL Determination: Dealing with the Unexpected
The International Standards for Functional Safety (IEC 61508 and IEC 61511) are well recognised and have been adopted globally in many of the industrialised countries during the past 10 years or so. Conformance with these standards involves determination
A. King
doaj +1 more source
This article addresses some functional safety assessment procedures with cybersecurity aspects in critical industrial installations with regard to the functional safety requirements specified in standards IEC 61508 and IEC 61511.
MARCIN ŚLIWIŃSKI +2 more
doaj +1 more source
Safety Risk Assessment; Using Fuzzy Failure Mode and Effect Analysis and Fault Tree Analysis [PDF]
The failure mode and effects analysis (FMEA) is a qualitative, Inductive and effective method for detecting errors, faults, and failures in a system and fuzzy logic can improve that technique with more logical outputs.
Mazdak Khodadadi-Karimvand +1 more
doaj +1 more source
In order to further promote the regional management mode of oil and gas pipelines, evaluate the adequacy of existing protection measures for the typical stations and enhance the risk control capability thereof, the safety integrity level(SIL) of the ...
Yu DIAO +5 more
doaj +1 more source