Results 201 to 210 of about 1,120,551 (376)

From 2D to 3D gamma passing rate tolerance and action limits for patient‐specific quality assurance in volumetric‐modulated arc therapy

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background Volumetric modulated arc therapy (VMAT) requires an accurate patient‐specific quality assurance (PSQA) program. In clinical practice, this is usually performed using the γ‐index and the two‐dimensional gamma passing rate (2D %GP). A three‐dimensional (3D) index incorporating the patient anatomy could be more useful for the 3D dose ...
Christos Zarros   +6 more
wiley   +1 more source

Dose rate correction of a diode array for universal wedge field dosimetric verification

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose To study the performance of MapCHECK 3 (MC3) in measuring universal wedge fields and propose a dose rate correction strategy to improve MC3 measurement accuracy. Materials and methods Universal wedge fields with different wedge angles and field sizes were measured at different depths using MC3.
Linyi Shen   +6 more
wiley   +1 more source

Digital Light Processing of 2D Lattice Composites for Tunable Self‐Sensing and Mechanical Performance

open access: yesAdvanced Engineering Materials, EarlyView., 2023
The study presents the mechanical and in situ sensing performance of digital light processing‐enabled 2D lattice nanocomposites under monotonic tensile and repeated cyclic loading, and provides guidelines for the design of architectures suitable for strain sensors and smart lightweight structures.
Omar Waqas Saadi   +3 more
wiley   +1 more source

Monte Carlo modeling of radiation dose from radiation therapy with superficial x‐rays

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Introduction Superficial x‐rays (50–100 kVp) are used for treating non‐melanoma skin cancer and intraoperative radiation therapy (IORT). At these energies, the photoelectric effect significantly increases absorbed dose to bone compared to soft tissue.
Reham Barghash   +3 more
wiley   +1 more source

A Variational Beam Model for Failure of Cellular and Truss‐Based Architected Materials

open access: yesAdvanced Engineering Materials, EarlyView., 2023
Herein, a versatile and efficient beam modeling framework is developed to predict the nonlinear response and failure of cellular, truss‐based, and woven architected materials. It enables the exploration of their design space and the optimization of their mechanical behavior in the nonlinear regime. A variational formulation of a beam model is presented
Konstantinos Karapiperis   +3 more
wiley   +1 more source

Home - About - Disclaimer - Privacy