Results 251 to 260 of about 1,699,007 (283)
Some of the next articles are maybe not open access.

Stress corrosion cracking of NiTi in artificial saliva

Dental Materials, 2007
This paper aimed to study the mechanism of the cracking of orthodontic NiTi wire.Two orthodontic NiTi wires were subjected: (1) optical and scanning electron microscopy (SEM) to observe the fracture surface; (2) energy dispersive X-ray spectroscopy to determine the composition of the surface product; (3) anodic polarization to remove the surface ...
Jianqiu, Wang   +4 more
openaire   +2 more sources

Artificial G-load and chemical changes of saliva

Acta Astronautica, 1994
Effectiveness of artificial G load is expected when it is used as a countermeasure against various bio-medical mishaps which are taking place in the micro-gravity environment, and probably more importantly, to prepare re-entry to the earth 1-G environment.
M, Igarashi   +3 more
openaire   +2 more sources

Corrosion of gold alloys and titanium in artificial saliva

European Journal of Oral Sciences, 1982
Abstract – Two types of gold alloys and one type of pure titanium have been submitted to corrosion in artificial saliva for periods of up to about 2 months. The release of copper, gold or silver from the golod alloys as well as titanium from the titanium matrix was measured with nuclear tracer technique.
D, Brune, D, Evje, S, Melsom
openaire   +2 more sources

Artificial saliva reservoirs

The Journal of Prosthetic Dentistry, 1984
Vissink, A.   +6 more
openaire   +3 more sources

Artificial Salivas: Why Are They Not More Useful?

2014
The potential market for artificial salivas is huge, yet the actual usage is relatively low. One reason may be the lack of effectiveness of current brands. At best they only mimic the viscous nature of saliva but not the other physical properties, such as elasticity.
openaire   +1 more source

XEROSTOMIA AND ARTIFICIAL SALIVA

Australian Dental Journal, 1982
openaire   +2 more sources

Dissolution of stainless steel in artificial saliva.

The International journal of oral & maxillofacial implants, 1997
Dissolution of stainless steel type 304 in artificial saliva was studied by electrochemical methods, electron spectroscopy for chemical analysis, and atom absorption spectroscopy. The samples were polarized in the -400 mV (saturated calomel electrode) to -50 mV (saturated calomel electrode) range. The total thickness of the passive film was found to be
M, Lakatos-Varsányi   +2 more
openaire   +1 more source

Artificial salivas

The Journal of the American Dental Association, 2001
openaire   +1 more source

Home - About - Disclaimer - Privacy