Results 21 to 30 of about 15,581,970 (330)

Influence of double solution treatment on hardness in 17-4 pH steel

open access: yesZaštita Materijala, 2015
The investigated material is a corrosion-resistant, Cu precipitation hardened steel 17-4PH, which undergoes a macroscopic contraction, as a result of applying the following heat treatment: double solution treatment at 1028°C for 1 h (condition A), ageing
Roman Sowa   +4 more
doaj   +1 more source

Bacterial Metabolomics: Sample Preparation Methods

open access: yesBiochemistry Research International, 2022
Metabolomics is a comprehensive analysis of metabolites existing in biological systems. As one of the important “omics” tools, the approach has been widely employed in various fields in helping to better understand the complex cellular metabolic states ...
Khairunnisa Mohd Kamal   +5 more
semanticscholar   +1 more source

Sample Preparation: The Forgotten Beginning [PDF]

open access: yes, 2009
Advances in molecular technologies and automated instrumentation have provided many opportunities for improved detection and identification of microorganisms; however, the upstream sample preparation steps needed to apply these advances to foods have not ...
Brehm-Stecher, Byron   +4 more
core   +3 more sources

Development of thin film microextraction method for the multi-residue analysis of selected pesticides

open access: yesAdvances in Sample Preparation, 2023
Pesticides are a class of compounds that are used to protect agricultural products. However, the uncontrolled use of these chemicals increases the risks associated with their overdosing and rises a significant concern about their effect on human health ...
Kübra Kahremanoğlu   +2 more
doaj   +1 more source

Magnetic nanoparticles for removing inorganic arsenic species from waters: A proof of concept for potential application

open access: yesAdvances in Sample Preparation, 2023
Inorganic arsenic is considered one of the most critical and severe environmental problems due to its high toxicity even at low levels of exposure, causing serious health problems.
Yesica Vicente-Martínez   +4 more
doaj   +1 more source

Automated processing of whole blood samples for the determination of immunosuppressants by liquid chromatography tandem-mass spectrometry [PDF]

open access: yes, 2006
Background: Liquid chromatography tandem-mass spectrometry (LC-MS/MS) is an efficient technology for routine determination of immunosuppressants in whole blood; however, time-consuming manual sample preparation remains a significant limitation of this ...
Spöhrer, Ute, Vogeser, Michael
core   +1 more source

Purge and trap in-tube colorimetric detection method for the determination of ethanol in alcoholic and non-alcoholic beverages

open access: yesAdvances in Sample Preparation, 2022
A simple and cost-effective analytical approach based on the combination of purge and trap technique coupling with smartphone-based image analysis was developed for the sensitive detection of ethanol.
Waleed Alahmad   +5 more
doaj   +1 more source

Novel critical point drying (CPD) based preparation and transmission electron microscopy (TEM) imaging of protein specific molecularly imprinted polymers (HydroMIPs) [PDF]

open access: yes, 2007
We report the transmission electron microscopy (TEM) imaging of a hydrogel-based molecularly imprinted polymer (HydroMIP) specific to the template molecule bovine haemoglobin (BHb).
Andreas Holzenburg   +21 more
core   +1 more source

Uncertainties of size measurements in electron microscopy characterization of nanomaterials in foods [PDF]

open access: yes, 2015
Electron microscopy is a recognized standard tool for nanomaterial characterization, and recommended by the European Food Safety Authority for the size measurement of nanomaterials in food.
Boxall, A. B. A.   +6 more
core   +1 more source

Vacuum-assisted headspace solid-phase microextraction and gas chromatography coupled to mass spectrometry applied to source rock analysis

open access: yesAdvances in Sample Preparation, 2022
Vacuum-assisted headspace solid phase microextraction (Vac-HSSPME) with high temperature of extraction was used for source-rock analysis. Optimization of extraction conditions was performed by Doehlert experimental design (DD) in gas chromatography ...
Breno J. Pollo   +4 more
doaj   +1 more source

Home - About - Disclaimer - Privacy