Results 191 to 200 of about 292,024 (345)

Deformations of the scalar curvature of a partially integrable pseudohermitian manifold [PDF]

open access: yesarXiv
We consider deformations of the scalar curvature of a partially integrable pseudohermitian manifold, in analogy with the work of Fischer and Marsden on Riemannian manifolds. In particular, we introduce and discuss $R$-singular spaces, give sufficient conditions for the stability of the scalar curvature, and give a partial infinitesimal rigidity result ...
arxiv  

Calibration and volunteer testing of a prototype contactless respiratory motion detection system based on laser tracking

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose The goal of this study was to assess the feasibility of a cost‐effective prototype of a laser‐based respiratory motion detection system utilizing a Leuze LDS for breath monitoring through calibration and volunteer tests. Methods This study was performed using the Anzai AZ‐773 V and computerized imaging reference systems (CIRS) motion ...
Isnaini Nur Islami   +6 more
wiley   +1 more source

Improving VMAT dose calculation accuracy and planning quality via a GPU‐accelerated Fourier transform dose calculation algorithm

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background Inverse planning typically utilizes fast, less accurate dose calculation algorithms during the iterative optimization process, thus leading to dose calculation errors (DCEs) and suboptimal plans that often require dose normalization and/or plan re‐optimization.
Kenny Guida   +4 more
wiley   +1 more source

Evaluation of OPTOS wide‐field fundus image projections for radiotherapy planning of uveal melanoma

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose To investigate the relationship between the stereographic and azimuthal equidistant projection (AEP) of the human retina for radiotherapy planning with OPTOS optomap wide‐field fundus images (Optos, UK). Further, the geometric accuracy of an OPTOS fundus image is quantified.
Jörg Wulff   +7 more
wiley   +1 more source

High spatial resolution dosimetry for radiation oncology with “MagicPlates,” a new 976‐pixel monolithic silicon detector

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose We introduce the next generation of “MagicPlate” 2D monolithic pixelated semiconductor detectors – MagicPlate‐976 (MP976). It features a larger array area, higher spatial resolution, and does not require external triggering. We perform a comprehensive characterization for small‐field steep‐dose‐gradient dosimetry applications in ...
Ilia Filipev   +13 more
wiley   +1 more source

Home - About - Disclaimer - Privacy