Scanning-electron-microscope used in real-time study of friction and wear [PDF]
Small friction and wear apparatus built directly into scanning-electron-microscope provides both dynamic observation and microscopic view of wear process.
Brainard, W. A., Buckley, D. H.
core +1 more source
Kelvin Probe Spectroscopy of a Two-Dimensional Electron Gas Below 300 mK
A scanning force microscope with a base temperature below 300 mK is used for measuring the local electron density of a two-dimensional electron gas embedded in an Ga[Al]As heterostructure. At different separations between AFM tip and sample, a dc-voltage
Copeland J. A. +7 more
core +1 more source
This study explores the lightweight potential of laser additive‐manufactured NiTi triply periodic minimal surface sheet lattices. It systematically investigates the effects of relative density and unit cell size on surface quality, deformation recovery, compression behavior, and energy absorption.
Haoming Mo +3 more
wiley +1 more source
Persistence pays off: Sir Charles Oatley and the scanning electron microscope [PDF]
Shortly after World War II, Sir Charles Oatley initiated research at the Cambridge University engineering laboratories on what has evolved into the modern scanning electron microscope.
Everhart, T. E.
core +1 more source
This study demonstrates an efficient recycling route for out‐of‐spec AlSi10Mg atomized powders through compaction and arc remelting followed by suction casting. By correlating compaction load, cooling rate, and resulting microstructure, we show that intermediate pressures (50–80 kN) and rapid cooling refine dendrites, reduce porosity, and enhance ...
Mila Christy de Oliveira +4 more
wiley +1 more source
The trajectories of secondary electrons in the scanning electron microscope [PDF]
AbstractThree‐dimensional simulations of the trajectories of secondary electrons (SE) in the scanning electron microscope have been performed for plenty of real configurations of the specimen chamber, including all its basic components. The primary purpose was to evaluate the collection efficiency of the Everhart‐Thornley detector of SE and to reveal ...
Ivo, Konvalina, Ilona, Müllerová
openaire +2 more sources
A Compact Spin‐Coated Graphene UWB Antenna for Breast Tumor Detection
A compact, spin‐coated graphene ultra‐wideband patch antenna designed for breast tumor detection, capable of distinguishing between malignant and benign tumors. This innovative antenna can serve as an effective initial screening tool, particularly in resource‐limited settings such as rural areas, where access to advanced medical equipment like MRI and ...
Raja Rashidul Hasan +9 more
wiley +1 more source
Experimental stress-strain analysis of tapered silica optical fibers with nanofiber waist
We experimentally determine tensile force-elongation diagrams of tapered optical fibers with a nanofiber waist. The tapered optical fibers are produced from standard silica optical fibers using a heat and pull process. Both, the force-elongation data and
Hoinkes, Thomas +4 more
core +1 more source
This study presents an infrared monitoring approach for direct laser interference patterning (DLIP) combined with a convolutional neural network (CNN). Thermal emission data captured during structuring are used to predict surface topography parameters.
Lukas Olawsky +5 more
wiley +1 more source
Nanoscale Estimation of Coating Thickness on Substrates via Standardless BSE Detector Calibration
The thickness of electron transparent samples can be measured in an electron microscope using several imaging techniques like electron energy loss spectroscopy (EELS) or quantitative scanning transmission electron microscopy (STEM).
Radim Skoupy +2 more