A soft, dual‐channel hydrogel patch enables simultaneous detection of wound temperature and strain by integrating ion‐diffusion‐mediated thermoelectric and resistive sensing. The conformal design maintains stable performance during motion, capturing subtle inflammatory and mechanical changes for continuous wound monitoring.
Yu Fang +7 more
wiley +1 more source
A New Quantitative Metric for Precise Classification of Diabetic Podocyte Injury Using Scanning Electron Microscopy. [PDF]
Rooney F +3 more
europepmc +1 more source
Here, we provide the reader with the current state of the art in the fabrication of high‐T2‐coherence diamond, optimized through the use of double electron–electron resonance (DEER) spectroscopy. We reveal the main as well as yet unidentified spin defects, the reduction of which is essential for reducing the spin bath and fabricating materials for ...
Olga Rubinas +6 more
wiley +1 more source
Characterization of core/shell bi-metallic cube-shaped nanoparticles with scanning transmission electron microscopy [PDF]
Anjum, Dalaver H. +2 more
core +1 more source
Effectiveness of a nanoemulsion-containing Nigella sativa nanoparticles encapsulated in propolis nanomicelles on dentin tubule occlusion: An scanning electron microscopy study. [PDF]
Shadman N +5 more
europepmc +1 more source
A swelling‐programmed micropatterned hydrogel guides adherent cells through a controlled transition from cell–matrix anchoring to cadherin‐mediated cell–cell compaction, enabling rapid assembly of high‐viability spheroids with defined size and morphology.
Han Gyeol Nam +8 more
wiley +1 more source
Evaluation of biofilm disruption on root dentin following conventional and nanoparticle-enhanced photodynamic therapies using scanning electron microscopy and FIJI-based image analysis. [PDF]
Jouhar R, Halim MS, Quadri SA, Ahmed MA.
europepmc +1 more source
Fully additive vertical organic electrochemical transistors (vOECTs) with channel‐length of 226 nm on a 50 µm compostable substrate achieve >106 current modulation and ∼36 mS transconductance. Ion‐selective integration enables 1.1 mA dec−1 sensitivity and 36 µm detection limit, highlighting a scalable platform for sustainable electronics and ...
Giulia Frusconi +3 more
wiley +1 more source
Comparative analysis of apical root resorption induced by different intrusion mechanics: A scanning electron microscopy study. [PDF]
Sonwane S +5 more
europepmc +1 more source
In situ Auger Electron Spectroscopy resolves oxidation states with high fidelity during the pulsed laser deposition of multivalent perovskite manganate and vanadate heterostructures. The chemical‐state signature is carried by the valence‐electron population of the transition‐metal cation, read out through the relative intensities of Auger fine ...
Harish Kumarasubramanian +1 more
wiley +1 more source

