Results 121 to 130 of about 5,368 (222)
Multimodal Assessment of Structure and Function in Inherited Retinal Degenerations [PDF]
Inherited retinal degenerations (IRDs) affect approximately 1:4,000 people worldwide and are currently the leading cause of vision loss of people between the ages of 15-45. The mechanisms of degeneration in many IRDs remain unclear.
Foote, Katharina
core
Scanning laser ophthalmoscopy of the optic nerve head in exfoliation glaucoma and ocular hypertension with exfoliation syndrome [PDF]
Mika Harju
openalex +1 more source
Adaptive optics scanning laser ophthalmoscope imaging: technology update
David Merino, Pablo Loza-Alvarez The Institute of Photonic Sciences (ICFO), The Barcelona Institute of Science and Technology, Castelldefels, Barcelona, Spain Abstract: Adaptive optics (AO) retinal imaging has become very popular in the past few years,
Merino D, Loza-Alvarez P
doaj
\u3cem\u3eIn vivo\u3c/em\u3e Imaging of Human Cone Photoreceptor Inner Segments [PDF]
Purpose. An often overlooked prerequisite to cone photoreceptor gene therapy development is residual photoreceptor structure that can be rescued. While advances in adaptive optics (AO) retinal imaging have recently enabled direct visualization of ...
Carroll, Joseph +6 more
core +1 more source
Increasing the field of view of adaptive optics scanning laser ophthalmoscopy
An adaptive optics scanning laser ophthalmoscope (AO-SLO) set-up with two deformable mirrors (DM) is presented. It allows high resolution imaging of the retina on a 4°×4° field of view (FoV), considering a 7 mm pupil diameter at the entrance of the eye.
Laslandes, Marie +3 more
openaire +2 more sources
\u3cem\u3eIn vivo\u3c/em\u3e Dark-field Imaging of the Retinal Pigment Epithelium Cell Mosaic [PDF]
Non-invasive reflectance imaging of the human RPE cell mosaic is demonstrated using a modified confocal adaptive optics scanning light ophthalmoscope (AOSLO). The confocal circular aperture in front of the imaging detector was replaced with a combination
Dubra, Alfredo +2 more
core +1 more source
Atlas of Laser Scanning Ophthalmoscopy [PDF]
Päivi Puska, Mika Harju
openaire +1 more source
Speed quantification and tracking of moving objects in adaptive optics scanning laser ophthalmoscopy [PDF]
Johnny Tam, Austin Roorda
openalex +1 more source
Purpose The aim of this study was to evaluate the ultra-wide field (UWF) scanning laser ophthalmoscopy using the Optomap 200Tx (Optos) in detecting peripheral retinal lesions in myopic patients.
Amr M Elhady, Osama R Elnaggar
doaj +1 more source

