Results 91 to 100 of about 16,042 (270)
Corneal biomechanical properties in myopic eyes evaluated via Scheimpflug imaging
Background To investigate the biomechanical properties of the cornea in myopic eyes using corneal visualization Scheimpflug technology (Corvis ST). The relationships between the biomechanical properties of the cornea and the degree of myopia were also ...
A. Yu +8 more
semanticscholar +1 more source
Background In recent years, increasing interest has arisen in the application of data from corneal biomechanics in many areas of ophthalmology, particularly to assist in the detection of early corneal ectasia or ectasia susceptibility, to predict corneal
P. Baptista +4 more
semanticscholar +1 more source
Keratoconus Detection Based on a Single Scheimpflug Image
To introduce a new approach for keratoconus detection based on corneal microstructure observed in vivo derived from a single Scheimpflug image.Scheimpflug single-image snapshots from 25 control subjects and 25 keratoconus eyes were analyzed; from each group, five subjects were randomly selected to provide out-of-sample data.
Consejo, Alejandra +5 more
openaire +3 more sources
Purpose To compare the difference, correlation, and agreement of anterior chamber parameters measured by Pentacam and CASIA 2. Methods A total of 89 myopic patients (89 right eyes) of Beijing Tongren Hospital were included. Anterior chamber depth (ACD), anterior chamber volume (ACV), and anterior chamber angle (ACA) were measured by Pentacam and CASIA ...
Yi Fan Li +4 more
wiley +1 more source
Biomechanical Measurement of Rabbit Cornea by a Modified Scheimpflug Device
Purpose. To explore the probability and variation in biomechanical measurements of rabbit cornea by a modified Scheimpflug device. Methods. A modified Scheimpflug device was developed by imaging anterior segment of the model imitating the intact eye at ...
Bo Zhang +5 more
doaj +1 more source
Purpose: To analyze single session, intrauser reliability of a Scheimpflug device for anterior chamber (AC) and corneal parameters. Methods: In this observational study, 100 normal candidates underwent Scheimpflug analysis with Sirius 3D Rotating ...
Gaurav Prakash, Dhruv Srivastava
doaj +1 more source
Non-contact methods for the detection of people at risk of primary angle closure glaucoma [PDF]
This is a protocol for a Cochrane Review (Diagnostic test accuracy). The objectives are as follows: To determine the diagnostic accuracy of non-contact screening methods for identifying eyes with a narrow ...
Alsbirk +38 more
core +1 more source
One‐Year Outcomes of Topography‐Guided LASIK for Myopia and Astigmatism
Introduction To assess the efficacy and safety of topography‐guided LASIK (TG‐LASIK) in correcting myopia and astigmatism and to evaluate clinical outcomes and visual quality postoperatively. Methods We conducted a prospective study including patients aged 18–40 years with stable refraction for over 12 months.
Shanshan Wei +8 more
wiley +1 more source
Double-pass technique and compensation-comparison method in eyes with cataract [PDF]
PURPOSE To clinically assess the objective scatter index (OSI) obtained from double-pass images and the log(s) parameter measured with the direct compensation-comparison psychophysical technique in eyes with cataract.
Almudí Cortés, Lorena +7 more
core +2 more sources
Subject To assess the precision (repeatability and reproducibility) and agreement of central corneal thickness (CCT) measurements by a high‐resolution ultrasound (E‐pach), a standard ultrasound, and two Scheimpflug pachymeters in healthy eyes. Methods Instrument diagnostic test study. A total of 100 healthy volunteers were enrolled to measure right‐eye
Anqi Liu +9 more
wiley +1 more source

