Results 21 to 30 of about 2,262 (162)
Diagnostic Value of Modern Methods of Ocular Anterior Segment Visualization in Intumescent Cataract
Purpose: tо evaluate the diagnostic capabilities of optical coherence tomography (OCT), Scheimpflug camera and ultrasound biomicroscopy (UBM) in examining topography of the ocular anterior segment and lens in mature intumescent cataract.
O. L. Fabrikantov +2 more
doaj +1 more source
Geometric model of image formation in Scheimpflug cameras [PDF]
We present a geometric model of image formation in Scheimpflug cameras that is most general. Scheimpflug imaging is commonly used is scientific and medical imaging either to increase the depth of field of the imager or to focus on tilted object surfaces. Existing Scheimpflug imaging models do not take into account the effect of pupil magnification (i.e.
Sinharoy, Indranil +2 more
openaire +1 more source
Comparison of Confocal Microscopy and Scheimpflug Camera Findings in Avellino Corneal Dystrophy
In this case report, a literature-guided comparative analysis of confocal microscopy and Scheimpflug camera findings of an adult with Avellino corneal dystrophy was performed.
Murat Küçükevcilioğlu +3 more
doaj +1 more source
Diagnosis of keratoconus with optical coherence tomography
Purpose The aim of the study was to assess the accuracy of optical coherence tomography (OCT) (3D OCT-2000) in diagnosing keratoconus by measuring the central corneal thickness and the central curvature radius.
Mortada A Abozaid, Ashraf M Mohammed
doaj +1 more source
Forme Fruste Keratoconus Imaging and Validation via Novel Multi-Spot Reflection Topography
Background/Aims: This case report aims to evaluate safety, efficacy and applicability of anterior surface imaging in a patient with forme fruste keratoconus (FFKC) based on a novel multi-spot, multicolor light-emitting-diode (LED) tear film-reflection ...
Anastasios John Kanellopoulos +1 more
doaj +1 more source
This paper aimed to develop and validate a deep learning (DL) model for automated detection of the laterality of the eye on anterior segment photographs.
Ce Zheng +9 more
doaj +1 more source
Monitoring of central corneal thickness after phacoemulsification—comparison of statical and rotating Scheimpflug pachymetry, and spectral-domain OCT [PDF]
AIM: To explore the possibility of deploying three contactless devices (static and rotating Scheimpflug technology, spectral domain optical coherence tomography) for measuring central corneal thickness (CCT) in preoperative and postoperative examinations
Daniel M. Handzel +2 more
doaj +1 more source
Comparison of Different Topographic Reference Surfaces in Keratoconus Cases
OBJECTİVE: To compare the sensitivity and specificity of elevation maps obtained from different topographical reference surfaces used in the diagnosis of keratoconus.
Ahmet Elbeyli +3 more
doaj +1 more source
Purpose: The purpose of this study was to compare the central corneal thickness (CCT) measurements of four noncontact devices in healthy eyes. Materials and Methods: In a sample of 45 healthy controls, CCT was measured using an optical biometer ...
Erhan Ozyol, Pelin Özyol
doaj +1 more source
Camera Calibration Considering Scheimpflug Condition
Presently, a new calibration scheme for the camera under the Scheimpflug condition is proposed, which represents an exact projection from the object through the lens to the inclined image sensors and also handles the distortion by the lens theoretically.
WATANABE, Atsushi +4 more
openaire +2 more sources