Log file‐based quality assurance method for respiratory gating system
Abstract Background As medical linear accelerator technology advances, enabling higher dose rate deliveries, hypofractionation regimens has increased. This necessitates respiratory gating systems that synchronize radiation delivery with tumor position, requiring simple rigorous quality assurance (QA) to ensure treatment accuracy and patient safety ...
Wonjoong Cheon+7 more
wiley +1 more source
O trabalho teve por objetivo determinar o prognóstico do aproveitamento escolar conforme a exposição ao retardo do crescimento ocorrido nos primeiros anos de vida.
Doris Lucia M. Lei+3 more
doaj
School health services in the Southern District of Israel-between privatization and nationalization. [PDF]
Dadon T+3 more
europepmc +1 more source
Accounting for TLD response to CBCT protocols in external beam radiotherapy dose monitoring
Abstract Purpose LiF thermoluminescent dosimeters (TLDs) are commonly used in radiation therapy to verify the delivered dose. Examples include dose verification for complicated treatment setups or cardiovascular implantable electronic devices (CIEDs). TLDs may be present for both the pre‐treatment imaging kilovoltage (kV) beam and the megavoltage (MV ...
Andrew J. White+5 more
wiley +1 more source
Psychometric Properties for the Safety Attitudes Questionnaire in Child and Youth Health Clinics and School Health Services: A Validation Study. [PDF]
Oma Langeland I+6 more
europepmc +1 more source
Developing reference plans for evaluating global clinical trials credentialing and PSQA systems
Abstract Purpose To develop a practical framework for creating a diverse set of validated reference plans (varying in complexity) and implement a workflow to introduce beam modeling, calibration, and delivery errors into the reference cohort to test and compare various dosimetry audit methodologies.
Fre'Etta M. D. Brooks+13 more
wiley +1 more source
Long-term evaluation of Helicobacter pylori screening in school health checkups: an 11-year study in Japan. [PDF]
Okamura T+6 more
europepmc +1 more source
Quantitative quality control of 3D water tank using image analysis
Abstract Background and objective Accurate beam data acquisition using three‐dimensional (3D) water tanks is essential for beam commissioning and quality control (QC) in clinical radiation therapy. This study introduces a novel method for quantitative QC of the system, utilizing MV images and webcam videos.
Yuki Tanimoto+9 more