Results 251 to 260 of about 21,085,562 (347)

Diagnostic image‐based treatment planning for online adaptive ultra‐hypofractionated prostate cancer radiotherapy with MR‐Linac

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose A new workflow was investigated for Elekta Unity MR‐Linac by removing the computed tomography (CT)‐simulation step and using diagnostic CT (DCT) for reference plan generation. Materials and methods Ten patients with ultra‐hypofractionated prostate cancer treated with magnetic resonance imaging (MRI)‐guided adaptive radiotherapy were ...
Yuan Xu   +5 more
wiley   +1 more source

Position‐dependent offset corrections for ring applicator reconstruction in cervical cancer brachytherapy

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Due to the tight curvature in their design, ring applicators are usually associated with large positioning errors. The standard practice to correct for these deviations based on global offsets may not be sufficient to comply with the recommended tolerance.
Leon G. Aldrovandi   +3 more
wiley   +1 more source

BreastWatch: A Varian Eclipse script tool for Community‐Based automatic evaluation of breast treatment plans

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This work introduces BreastWatch, a Varian Eclipse script tool designed to help medical physicists, dosimetrists, and radiation oncologists easily inspect and improve External Beam Breast Treatment (EBBT) plans using automatic evaluation of protocol dose‐constraints enhanced by a Community‐Based approach.
Stefano Agostinelli   +8 more
wiley   +1 more source

Durably reducing partisan animosity through multiple scalable treatments. [PDF]

open access: yesProc Natl Acad Sci U S A
Hall MEK   +5 more
europepmc   +1 more source

Open‐source deep‐learning models for segmentation of normal structures for prostatic and gynecological high‐dose‐rate brachytherapy: Comparison of architectures

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background The use of deep learning‐based auto‐contouring algorithms in various treatment planning services is increasingly common. There is a notable deficit of commercially or publicly available models trained on large or diverse datasets containing high‐dose‐rate (HDR) brachytherapy treatment scans, leading to poor performance on images ...
Andrew J. Krupien   +8 more
wiley   +1 more source

Professionalism skills education in medical physics residency: Current state and perceived importance

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose The purpose of this study was to collect data on current practices for teaching and assessing professionalism in CAMPEP‐accredited residency programs. Methods A survey of 21 questions was sent to 160 program directors (PDs) of CAMPEP‐accredited residency programs.
Anna Rodrigues   +5 more
wiley   +1 more source

Correction: One-year outcomes in sepsis: a prospective multicenter cohort study in Japan. [PDF]

open access: yesJ Intensive Care
Liu K   +27 more
europepmc   +1 more source

Home - About - Disclaimer - Privacy