Results 91 to 100 of about 397 (141)
The AC-DC conversion system in the power system use generally the diode-bridge based rectifiers that cannot be reversible and causes high current distortion. Besides, they reduce the power factor and energy quality.
Melissa AIT HAMOU ALI +5 more
core +1 more source
Grid-integrated solar PV converter operation using data-driven hybrid control approach
This paper analyzed a data-driven hybrid approach to control the multifunctional H-bridge converter (MFHC) in grid-integration operation. It explores the control approach for both grid-supplying and grid-injecting modes.
Ravi Kumar Majji +2 more
doaj +1 more source
A THD-Based Fault Protection Method Using MSOGI-FLL Grid Voltage Estimator. [PDF]
Al Hanaineh W +5 more
europepmc +1 more source
In this paper, improved sonsorless direct power control (DPC) of three-phase rectifiers is presented. The new system are based on virtual flux (VF) and notch filter using Second Order Generalized Integrator frequency located loop SOGI-FLL estimator.
Senani, F, Rahab, A, Benalla, H
core +2 more sources
Analysis of modified plug-in electric vehicle charger controller with grid support functionalities. [PDF]
R B S, C V.
europepmc +1 more source
A Novel Design Method for SOGI-PLL for Minimum Settling Time and Low Unit Vector Distortion
Phase-locked loops (PLLs) are necessary in grid connected systems to obtain information about the frequency, amplitude and phase of the grid voltage. In stationary reference frame control, the unit vectors of PLLs are used for reference generation. It is
Kulkarni, Abhijit +3 more
core +1 more source
A Center-Tapped Transformer Based Multifunctional Single-Phase Converter with Wide DC-Bus Control. [PDF]
Obi AS, Lee SH, Jung HS, Jung JJ.
europepmc +1 more source
Reduced order generalized integrators with phase compensation for three-phase active power filter
Current regulation is a critical issue for the stable operation of three-phase active power filters (APF). The challenge of the current controller lies in how to track the high slew rate reference with zero steady-state error in a fast and accurate way ...
Xie, Chuan +9 more
core +1 more source
The Actual Exactness of a Fast RMS Correction during Abrupt Voltage Change. [PDF]
Danin Z, Amiel I, Miteva N, Averbukh M.
europepmc +1 more source
Photovoltaic-Based q-ZSI STATCOM with MDNESOGI Control Scheme for Mitigation of Harmonics
Static compensators (STATCOMs) are often used in distribution systems to enhance power quality. There is a need to enhance the performance of STATCOM to optimize its utilization and facilitate the provision of additional ancillary services.
Kanagaraj Nallaiyagounder +3 more
doaj +1 more source

