Results 61 to 70 of about 397 (141)
Design of a High-performance High-pass Generalized Integrator Based Single-phase PLL
Grid-interactive power converters are normally synchronized with the grid using phase-locked loops (PLLs). The performance of the PLLs is affected by the non-ideal conditions in the sensed grid voltage such as harmonics, frequency deviations and the dc ...
Kulkarni, Abhijit, John, Vinod
core +1 more source
This study presents a time‐domain method for calculating transient negative sequence currents in offshore wind power AC systems during asymmetric faults. A second‐order differential equation short‐circuit model is developed, incorporating positive and negative sequence decomposition and grid‐side converter control, to accurately predict fault current ...
Botong Li +4 more
wiley +1 more source
The open-winding driving system can improve power density and torque output capacity of the motor. However, the open-winding topology with a common direct current (DC) power supply provides a path for the zero-sequence current, which contributes to the ...
Qing Lu +3 more
doaj +1 more source
This paper presents an integrated control strategy for enhancing fault ride‐through in CLCC‐HVDC systems. By combining adaptive current deviation control with an improved voltage‐dependent current order limitation strategy, the method leverages CLCC's controllable commutation capabilities to sustain operation and expedite recovery during fault events ...
Menghao Wen +5 more
wiley +1 more source
Accurate flux estimation is essential for the implementation of a high-performance ac motor drive. However, it still faces some problems, which can better be projected by analyzing performances of existing flux estimators, implemented with either a pure ...
Zhao, Rende +3 more
core +1 more source
Voltage sags pose severe risks to sensitive equipment in modern industries, requiring power quality monitoring equipment to possess fast and accurate sag detection capabilities.
Jun Zhou +3 more
doaj +1 more source
Considering the low power loss and simple structure, an equivalent impedance model of digitally controlled LCL‐type inverter with a widely deployed capacitor‐current active damping feedback structure is built first. Then, according to the obtained model, the effects of digital time delay of control system and equivalent grid impedance on active damping
Jinhong Liu, Xiaobing Zhang, Baohua Wang
wiley +1 more source
To address the issue of mechanical resonance frequency detection in dual-inertia servo systems, this paper proposes an online identification method for mechanical resonance frequency using a low-pass filter and cascaded second-order generalized ...
Yongchao Zhang +5 more
core +1 more source
Journal of Genetic Counseling, Volume 34, Issue 6, December 2025.
Kimberly Zayhowski +3 more
wiley +1 more source
The coupling of multiple non‐ideal factors in rotary transformers causes position errors to include fundamental, secondary harmonic and higher‐order harmonic components. Existing self‐calibration methods mainly focus on the secondary harmonic, neglecting the fundamental and higher‐order harmonics. An improved self‐calibration method is proposed in this
Jialin Li +5 more
wiley +1 more source