Spinning-disc confocal microscopy in the second near-infrared window (NIR-II). [PDF]
AbstractFluorescence microscopy in the second near-infrared optical window (NIR-II, 1000–1350 nm) has become a technique of choice for non-invasivein vivoimaging. The deep penetration of NIR light in living tissue, as well as negligible tissue autofluorescence within this optical range, offers increased resolution and contrast with even greater ...
Zubkovs V +9 more
europepmc +5 more sources
Perfecting and extending the near-infrared imaging window
Moderate light absorption by bio-tissue is conducive to the imaging performance. The second near-infrared window is perfected as 900–1880 nm, and 2080–2340 nm is proposed as the third near-infrared window.
Zhe Feng +14 more
doaj +1 more source
Layer-by-layer assembled fluorescent probes in the second near-infrared window for systemic delivery and detection of ovarian cancer. [PDF]
Dang X +6 more
europepmc +2 more sources
BSA-Coated Gold Nanorods for NIR-II Photothermal Therapy
The second near infrared window is considered to be the optimal optical window for medical imaging and therapy as its capability of deep tissue penetration.
Shubi Zhao +7 more
doaj +1 more source
Summary: Background: Surgery is the cornerstone of colorectal cancer (CRC) treatment, yet complete removal of the tumour remains a challenge. The second near-infrared window (NIR-II, 1000–1700 nm) fluorescent molecular imaging is a novel technique ...
Xiaoyong Guo +12 more
doaj +1 more source
Bright Fluorophores in the Second Near-Infrared Window: HgSe/CdSe Quantum Dots
Main text: 9 pages, 4 figures.
Ananth Kamath +2 more
openaire +3 more sources
Second window near-infrared dosimeter (NIR2D) system for radiation dosimetry
Fiber-coupled scintillation dosimeters are a cost-effective alternative to the conventional ion chambers in radiation dosimetry. However, stem effects from optical fibers such as Cerenkov radiation incur significant errors in the readout signal. Here we introduce a second near-infrared window dosimeter, dubbed as NIR2D, that can potentially be used as ...
Tae Jin Kim +5 more
openaire +3 more sources
Bioimaging in the second near‐infrared (NIR‐II) window can help to obtain high‐resolution images and a high penetration depth. This study proposes an Au/Si bilayer plasmonic nanodisk (Au/Si ND) that has a resonance wavelength in the NIR‐II window caused ...
Jinhyung Lee +6 more
doaj +1 more source
Activatable polymer nanoagonist for second near-infrared photothermal immunotherapy of cancer
Precise control of immune response remains challenging for cancer immunotherapy. Here, the authors report on photothermally activatable semiconducting polymeric pro-agonist in response to second near-infrared window light for regulated photothermal ...
Yuyan Jiang +3 more
doaj +1 more source
In vivo photoacoustic lipid imaging in mice using the second near-infrared window. [PDF]
Photoacoustic imaging has emerged as a promising technique to improve preclinical and clinical imaging by providing users with label-free optical contrast of tissue. Here, we present a proof-of-concept study for noninvasive in vivo murine lipid imaging using 1210 nm light to investigate differences in periaortic fat among mice of different gender ...
Sangha GS, Phillips EH, Goergen CJ.