Results 11 to 20 of about 2,946 (263)
The use of isolation layer structures has been a proven and effective method in reducing the seismic dynamic response of tunnels. It is considered a crucial measure in enhancing the seismic capacity of tunnels.
Lun Dai +3 more
doaj +1 more source
Comparison study on seismic isolation design of RC frame structure based on two different codes [PDF]
With the development of building seismic isolation technology and the official release of the Isolation Code in September 2021, seismic isolation design in China will now rely on two foundational codes: the Seismic Code and the Isolation Code. This paper
Junyi Zhang, Jiawei Li, Zhiqiang Zhang
doaj +1 more source
A Study on Seismic Isolation of Shield Tunnel Using Quasi-Static Finite Element Method
Using a quasi-static method based on an axisymmetric finite element model for seismic response analysis of seismically isolated tunnels, the seismic isolation effect of the isolation layer is studied, and the seismic isolation mechanism of the isolation ...
Can Li +4 more
doaj +1 more source
Gravel cushions have been introduced as a practical and efficient seismic isolation technology to ensure the safety of nuclear power plants. This study investigated the seismic isolation effect of a gravel cushion by conducting a series of shaking table ...
Yingying Zhao +5 more
doaj +1 more source
Evaluation of the seismic performance of isolated electrical transformers under pulse-like excitations [PDF]
Damage sustained by electrical transformers in past strong earthquakes led to irrecoverable and severe economic losses. The seismic performance evaluation is associated with the loss of proper functioning of transformers.
Mohammad Mahmoudi +2 more
doaj +1 more source
IMPROVE THE EFFICIENCY OF SEISMIC WITH RUBBER MOUNTS ELEMENTS COMBINED WITH DRY FRICTION
The goal is to increase effectiveness of seismic isolation of buildings with flexible rubber-seismic isolation bearings (RSIB). In order to reduce the maximum displacement RSIB installed in the basement of frame buildings in seismic isolation system ...
A. D. Abakarov, Kh. M. Omarov
doaj +1 more source
SEISMIC PERFORMANCE OF BRIDGES ISOLATED WITH FPS [PDF]
The scope of the present study is focused on the evaluation of the seismic response of bridges isolated by single concave sliding pendulum isolators (FPS) for the different structural properties when the presence of the rigid abutment is considered or neglected (i.e., isolated viaducts).
Castaldo P., Amendola G.
openaire +3 more sources
The purpose of this study was to develop a vertical seismic isolation device essential for the three-dimensional seismic isolation design of nuclear power plant equipment.
Gyeong-Hoi Koo +4 more
doaj +1 more source
AbstractThis paper proposes a vertical distribution of seismic design load of seismically isolated buildings corresponding to diversity of seismic isolation devices such as hysteretic dampers and/or velocity‐dependent dampers. This proposed method is obtained from the relationship between response amplification caused by higher‐mode responses and key ...
Masahito Kobayashi +2 more
openaire +3 more sources
Seismic isolation system using rhombus link and leaf spring (Vertical isolation)
This paper deals with seismic isolation system with nonlinear characteristics for vertical ground motion. The vertical seismic isolation system consists of a rhombus shaped link mechanism, a tension coil spring, and a leaf spring.
Naoki IIJIMA +2 more
doaj +1 more source