Results 21 to 30 of about 743 (188)
Passive control systems that provide both stiffness and energy dissipation, such as viscoelastic dampers (VEs), offer a promising strategy for seismic retrofit of existing reinforced concrete (RC) buildings, especially critical facilities that must ...
Sennan Lee, Chun Jiang
doaj +1 more source
Seismic design and retrofit of bridges
The 1989 Loma Prieta, 1994 Northridge and 1995 Hyogo-ken nanbu earthquakes caused major damage to bridges and these events together with the research triggered as a consequence of the earthquakes has led to significant advances in bridge seismic design and retrofitting.
openaire +2 more sources
Seismic Isolation Devices for Protecting RC Buildings: The Frangipane School in Reggio Calabria
Seismic isolation devices, as known, are particularly efficient tools for the protection of newly designed or existing buildings and infrastructures and for the mitigation of maximum effects due to earthquakes. The highest is the vulnerability of a given
Raffaele Pucinotti +2 more
doaj +1 more source
Seismic Evaluation and Retrofit of Historical Churches
A methodology for evaluating the seismic response capacities of historical churches is presented. Specially calibrated performance objectives, including the issue of cultural value safety, and related acceptance criteria are formulated to this aim. A mixed displacement and strength-based control of response is carried out, by interpreting the results ...
Sorace, S, TERENZI, GLORIA
openaire +2 more sources
Geotechnical aspects on seismic retrofit [PDF]
Abstract In the paper numerical analysis of foundation of damaged masonry structure using finite element method is presented. Retrofitting of those structures has been performed using technology DC90. By retrofit design, the foundation structure is confined with the foundation collar, connected by anchors and in which the vertical stiffening elements
Žugić, Željko +2 more
openaire +1 more source
In India, Multi-storied structures built are deficient of land and have to carry maximum load. Earthquake could be a circumstance which might result in the failure of the structure. Buildings are to be created so that they are safe to live in and the structure before failure should possess ductile property.
Peerzada Waris Ahmad, Brahamjeet Singh
openaire +1 more source
Seismic analysis and design of tunnels within fault ground: A review
The research methods of seismic response of tunnels within fault ground, including field investigations, analytical solutions, physical experiments, and numerical simulations, and seismic countermeasures are discussed. The present study examines the shortcomings and limitations of the current research and design, and puts forward proposals for future ...
Xingda Wang +6 more
wiley +1 more source
Seismic Upgrade of an Existing Reinforced Concrete Building Using Steel Plate Shear Walls (SPSW)
Steel Plate Shear Walls (SPSW) provide significant lateral load capacity and can be utilized in the seismic retrofit and upgrade of existing reinforced concrete (r/c) buildings.
Niki Balkamou, George Papagiannopoulos
doaj +1 more source
ABSTRACT This study investigates the seismic response of moment‐resisting frames retrofitted with a stepping rocking wall, with emphasis on weak‐story mitigation and residual drift reduction under both ordinary and pulse‐like ground motions. Nonlinear response‐history analyses are conducted on 9‐story and 20‐story SAC Los Angeles frames.
Mehrdad Aghagholizadeh
wiley +1 more source
The present paper aims at inspecting the structural behaviour of a typical masonry aggregate located in the historical centre of Cercola, a municipality in the province of Naples.
Antonio Formisano +2 more
doaj +1 more source