Results 31 to 40 of about 16,789 (234)

Application of steel in refurbishment of earthquake-prone buildings

open access: yesGrađevinar, 2020
Refurbishment of existing buildings has become an increasingly topical issue in recent years. The recent Zagreb earthquake has also increased public awareness about the issue of sensitivity of old buildings to seismic loads.
Davor Skejić   +3 more
doaj   +1 more source

Experimental assessment and retrofit of full-scale models of existing RC frames [PDF]

open access: yes, 2002
PSD tests on two full-scale models of existing non-seismic resisting RC frame structures are described. The testing program covered several aspects, namely assessment of seismic performance of existing frames without and with infill panels ...
Molina, J., Pinto, A. V., Varum, H.
core   +1 more source

The influence of joints and composite floor slabs on effective tying of steel structures in preventing progressive collapse [PDF]

open access: yes, 2009
The event of the terrorist attack at 11th September 2001 in the USA has attracted increasing attention of researchers and engineers on progressive collapse of structures.
Hu   +14 more
core   +1 more source

Seismic analysis and design of tunnels within fault ground: A review

open access: yesDeep Underground Science and Engineering, EarlyView.
The research methods of seismic response of tunnels within fault ground, including field investigations, analytical solutions, physical experiments, and numerical simulations, and seismic countermeasures are discussed. The present study examines the shortcomings and limitations of the current research and design, and puts forward proposals for future ...
Xingda Wang   +6 more
wiley   +1 more source

Seismic performance enhancement of underground structure influenced by CFRP wrapping schemes

open access: yesUrban Lifeline
The seismic failure mechanism of underground structures showing structural collapse is attributed to the deformation incompatibility between the central columns and the sidewalls, especially the insufficient deformation capacity of the central columns ...
Chao Ma   +4 more
doaj   +1 more source

Seismic analyses of a R/C building: study of a retrofitting solution [PDF]

open access: yes, 2000
The preliminary experimental results from the tests on a 4-storey R/C frame structure are presented and discussed. The full-scale model is representative of the common practice of 40~50 years ago in most south European countries.
Carvalho, E. C.   +3 more
core   +1 more source

For the Few, Not the Many: Tracing the Residualist and Compensatory Nature of British Energy Support

open access: yesEnvironmental Policy and Governance, EarlyView.
ABSTRACT Drawing on extensive documentary analysis, this article traces the evolution of British energy policy support since World War II. It analyses shifts in policy design through two interpretive lenses: eligibility (residualist vs. universalist) and function (compensatory vs. preventive).
T. M. Croon   +4 more
wiley   +1 more source

Seismic Retrofit of an Existing RC Building With Isolation Devices Applied at Base

open access: yesFrontiers in Built Environment, 2020
Nowadays, seismic retrofit through isolation strategy represents a consolidated technique of protection against design earthquakes. This technique is also applied on existing structures extensively, due to the fact that it usually does not require any ...
Michele D'Amato   +2 more
doaj   +1 more source

Low‐Cost Friction‐Based Force‐Limiting Connection With Reduced Sensitivity to Machining Tolerances and Accelerated Repairability

open access: yesEarthquake Engineering &Structural Dynamics, EarlyView.
ABSTRACT This paper presents a novel yet practical friction‐based structural component design for low‐damage earthquake‐resistant structures. The proposed connection design is based on a conventional slotted‐bolted configuration with the novelty being the use of loose steel washer plates to establish the friction‐sliding interface.
Kaixin Chen   +7 more
wiley   +1 more source

Seismic Capacity of R/C Buildings Retrofitted with a V-Bracing System Equipped with a Novel Laterally Layered Friction Damper

open access: yesApplied Sciences, 2023
This study proposed a novel V-bracing system equipped with a laterally layered friction damper (LLFD), which can supplement the shortcomings of conventional vibration control systems and is applicable to existing reinforced concrete (R/C) buildings.
Bok-Gi Lee   +3 more
doaj   +1 more source