Results 81 to 90 of about 869 (171)

MMW‐FC: A novel railway fastener detecting method based on millimetre wave radar for train positioning

open access: yesIET Radar, Sonar &Navigation, Volume 18, Issue 7, Page 1094-1105, July 2024.
A novel method is proposed for rail fastener detection based on millimetre‐wave radar, which can accurately detect and enumerate the fasteners in real‐time as the train traverses its route. Under circumstances where GNSS signals remain unavailable for prolonged durations, precise train localisation can be accomplished by correlating the number of ...
Yangang Sun   +5 more
wiley   +1 more source

ELECTRO-MECHANICAL DATA FUSION FOR HEART HEALTH MONITORING [PDF]

open access: yes, 2022
Heart disease is a major public health problem and one of the leading causes of death worldwide. Therefore, cardiac monitoring is of great importance for the early detection and prevention of adverse conditions.
Yakut, Kemal
core   +1 more source

Reconstruction of 3-Axis Seismocardiogram from Right-to-left and Head-to-foot Components Using A Long Short-Term Memory Network

open access: yes, 2023
This pilot study aims to develop a deep learning model for predicting seismocardiogram (SCG) signals in the dorsoventral direction from the SCG signals in the right-to-left and head-to-foot directions ($\textrm{SCG}_x$ and $\textrm{SCG}_y$).
Rahman, Mohammad Muntasir   +1 more
core   +1 more source

Signal Processing Methods for Heart Rate Detection Using the Seismocardiogram [PDF]

open access: yes, 2016
Cardiac diseases are one of the major causes of death. Heart monitoring/diagnostic techniques have been developed over decades to address this concern. Monitoring a vital sign such as heart rate is a powerful technique for heart abnormalities detection ...
Mafi, Mahsa 1988-
core   +3 more sources

Editorial: Highlights in Heart Failure and Transplantation in 2021

open access: yesFrontiers in Cardiovascular Medicine, 2022
Matteo Cameli   +3 more
doaj   +1 more source

A Morphological Approach To Identify Respiratory Phases Of Seismocardiogram [PDF]

open access: yes, 2016
Respiration affects the cardiovascular system significantly and the morphology of signals relevant to the heart changes with respiration. Such changes have been used to extract respiration signal from electrocardiogram (ECG).
Taghizadeh Alamdari, Nasim
core   +1 more source

Novel blood pressure and pulse pressure estimation based on pulse transit time and stroke volume approximation

open access: yesBioMedical Engineering OnLine, 2018
Background Non-invasive continuous blood pressure monitors are of great interest to the medical community due to their value in hypertension management. Recently, studies have shown the potential of pulse pressure as a therapeutic target for hypertension,
Joonnyong Lee   +5 more
doaj   +1 more source

Diagnostic accuracy of seismocardiography compared with electrocardiography for the anatomic and physiologic diagnosis of coronary artery disease during exercise testing [PDF]

open access: yes, 1993
A multicenter study was performed to compare the diagnostic accuracy of a new technique, Seismocardiography, with that of electrocardiography for physiologically and anatomically significant ischemic coronary artery disease (CAD) during exercise stress ...
Bamrah, Virinderjit S.   +4 more
core   +1 more source

Utilizing Gyroscopes Towards the Automatic Annotation of Seismocardiograms

open access: yesIEEE Sensors Journal, 2017
This paper reports on the use of the rotational component of chest vibrations for the automatic annotation of seismogram (SCG) recordings for the first time. An inertial measurement unit consisting of a three-axis MEMS accelerometer and a three-axis MEMS gyroscope is used for recording chest vibrations.
Chenxi Yang   +2 more
openaire   +1 more source

Comparison of HRV indices obtained from ECG and SCG signals from CEBS database

open access: yesBioMedical Engineering OnLine, 2019
Background Heart rate variability (HRV) has become a useful tool of assessing the function of the heart and of the autonomic nervous system. Over the recent years, there has been interest in heart rate monitoring without electrodes.
Szymon Siecinski   +2 more
doaj   +1 more source

Home - About - Disclaimer - Privacy