Current compensation for material consumption of cobalt self-powered neutron detector
Co Self-Powered Neutron Detector (SPND) is confronted with the problem of material consumption, which causes the response current can neither reflect the change of neutron flux in time nor be proportional to the neutron flux.
Xinxin Liu +4 more
doaj +4 more sources
Study of neutron sensitivity for vanadium self-powered neutron detector in nuclear reactors
Vanadium self-powered neutron detectors (SPNDs) are widely used as in-core unmovable detectors in nuclear power plants to continuously carry out data monitoring of neutron flux and nuclear power.
Xiong Wu +4 more
doaj +3 more sources
Development of a Fast-Spectrum Self-Powered Neutron Detector for Molten Salt Experiments in the Versatile Test Reactor [PDF]
The self-powered neutron detector (SPND) is a widely used flux monitor in thermal nuclear reactors. Although this is a mature technology, the current state of the art is tuned for a thermal neutron spectrum, so many of the devices currently in use lack ...
Goetz K. C., Cetiner S. M., Celik C.
doaj +2 more sources
Self-Powered Neutron Detector Calibration Using a Large Vertical Irradiation Hole of HANARO [PDF]
A calibration technology of the self-powered neutron detectors (SPNDs) using a large vertical irradiation hole of HANARO is developed. The 40 Rh-SPNDs are installed on the polycarbonate plastic support, and the gold wires with the same length as the ...
Kim Myong-Seop +2 more
doaj +3 more sources
The Self-Powered Detector Simulation ‘MATiSSe’ Toolbox applied to SPNDs for severe accident monitoring in PWRs [PDF]
In the framework of the French National Research Agency program on nuclear safety and radioprotection, the ‘DIstributed Sensing for COrium Monitoring and Safety’ project aims at developing innovative instrumentation for corium monitoring in case of ...
Barbot Loïc +4 more
doaj +3 more sources
These investigation findings prove the possibility of a engineering solution for VVER core automatic protection during operation in both nominal and transient conditions within ICIS using local parameters (i.e. linear heat power of the most stressed fuel
Lys Stepan, Kanyuka Alexandr
doaj +2 more sources
Diagnostics of in-core neutron monitoring system based on artificial neural network
One of the tasks of the diagnostics of in-core neutron control is the task of diagnostics of self-powered neutron detectors, namely the determination of reliability of self-powered neutron detectors signal, that is, the detection of the fault self ...
Володимир Іванович Борисенко +2 more
doaj +5 more sources
Sorted compressive sensing for reconstruction of failed in-core detector signals
Self-Powered Neutron Detectors(SPNDs) are used to calculate core power distributions, an essential factor in the safe operation of nuclear power plants. Some detectors may fail during normal operation, and signals from failed detectors are isolated from ...
Gyu-ri Bae +3 more
doaj +1 more source
Design and simulation of a self-powered neutron spectrometer [PDF]
A self-powered neutron detector (SPND) is a device that, coupled with a current meter, provides a readout proportional to neutron population. This thesis discusses the design parameters of an array of such devices, their characteristics, and the use of ...
Kropp, Edward K.
core +5 more sources
MONACO v2: Multipurpose and Integrated Data Acquisition System for On-line Neutron and Gamma Measurements [PDF]
The CEA MONACO v2 a multichannel acquisition system dedicated to neutron and gamma measurements. It is unique as it integrates all the following features in one module: automatic generation of saturation curves, automatic generation of pulse ...
Barbot L. +6 more
doaj +1 more source

