Evaluating Harm Reduction Advice From Large Language Models
ABSTRACT Introduction Large language models (LLM) and generative Artificial Intelligence are increasingly providing health information. We have applied a novel method to evaluate the harm reduction information generated by popular LLMs. We focused on the filtration of oral medications for injection and the availability of local harm reduction services.
Khy Choo +3 more
wiley +1 more source
BOLTED TIMBER JOINTS WITH SELF-TAPPING SCREWS
The use of self-tapping screws with continuous threads in the joint area as a reinforcement to avoid splitting of timber members is studied. A theoretical model is developed to calculate the stress distribution around a pin-loaded hole in a timber joint, to predict brittle failure modes in bolted connections and to calculate the load in the reinforcing
openaire +2 more sources
Design concept for CLT - reinforced with self-tapping screws
Concentrated loads on Cross Laminated Timber elements (CLT) in areas of point supports or load applications cause high local shear stresses. Inclined self -tapping screws with continuous threads have turned out to be an effective reinforcement. As neither the German design standard DIN 1052 [2] nor technical approvals cover this construction method a ...
Mestek, Peter, Dietsch, Philipp
openaire +1 more source
Tensile Pull-Out Behaviour and Global Sensitivity Analysis of Fastening Screws in Photovoltaic Aluminium Support Structures. [PDF]
Zhang J +4 more
europepmc +1 more source
Surgical management of an unstable occipital condyle fracture in a dog using a patient-specific CNC-milled titanium implant: a case report. [PDF]
Jeong N, Kim H, Cho C, Jung J.
europepmc +1 more source
Zero-profile interbody fusion in single and two-level anterior cervical discectomy and fusion: a novel surgical system and its indications. [PDF]
Ng MK +5 more
europepmc +1 more source
A Synergistic Patient-Specific Approach for Enhanced Spinal Fixation Using a Novel Flexible Pedicle Screw and a Complementary Steerable Drilling Robotic System. [PDF]
Kulkarni Y +6 more
europepmc +1 more source
Influence of Screw Length and Bone Quality on Pedicle Screw Anchorage Under Cyclic Fatigue Loading. [PDF]
Roch FE +8 more
europepmc +1 more source
Rotational Stability in a Feline Sacroiliac Luxation Model: Biomechanical Comparison of Cannulated Compression Headless Screws and Cortical Screws Applied in Positional or Lag Fashion. [PDF]
Klement J +6 more
europepmc +1 more source
A Retrospective Analysis of Guidewireless Versus Guidewire-Assisted Navigated Percutaneous Pedicle Screw Placement for Minimally Invasive Spine Surgery at a Tertiary Care Institute. [PDF]
Dave MB +10 more
europepmc +1 more source

