Results 151 to 160 of about 93,624 (215)

Mapping Robusta coffee (Coffea canephora) cropping systems in Uganda: A two-step pixel and sub-pixel based approach with Sentinel-2 data. [PDF]

open access: yesPLoS One
Kebede G   +8 more
europepmc   +1 more source

Shaping the Future of Radiography Education: Lessons From ChatGPT and Generative AI

open access: yesJournal of Medical Radiation Sciences, EarlyView.
ChatGPT can provide structured guidance, support self‐assessment and scaffold learning processes that bridge classroom knowledge and clinical expectations. However, AI must be embedded in ways that uphold the core principles of radiographic practice: accuracy, reflective judgment, ethical reasoning, empathy and patient‐centred care.
Minh T. Chau   +5 more
wiley   +1 more source

Mapping the Landscape of Over‐Scanning in CT Imaging: A Scoping Review

open access: yesJournal of Medical Radiation Sciences, EarlyView.
Over‐scanning in CT is highly prevalent and contributes to unnecessary radiation exposure, with notable impact on radiosensitive organs. Standardised protocols and AI‐assisted planning show strong potential to optimise scan range and reduce excess dose.
Mo'men Bani‐Ahmad   +5 more
wiley   +1 more source

Size‐specific dose estimates calculated using patient size measurements from scanned projection radiograph in high‐resolution chest computed tomography

open access: yesJournal of Medical Radiation Sciences, Volume 72, Issue 1, Page 85-92, March 2025.
This study established that patient's lateral width measurements made from scanned projection radiograph (SPR) is an overestimate compared to those measured from tomographic slices by about 10%. Size‐specific dose estimates (SSDE) calculated using lateral width measured from SPR correlates well with SSDE calculated using water equivalent diameter of ...
Ajit Brindhaban
wiley   +1 more source

Sonographic localisation of lymph nodes suspicious of metastatic breast cancer to surgical axillary levels

open access: yesJournal of Medical Radiation Sciences, Volume 72, Issue 1, Page 119-138, March 2025.
Sonographic imaging is used to identify the presence, number and location of malignant lymph nodes. Axillary lymph nodes suspicious of harbouring breast cancer metastasis can be localised to three surgical axillary levels. This paper will unpack the axillary anatomy, muscular sonographic landmarks, surgical axillary lymph node levels and the ...
Michelle Fenech   +4 more
wiley   +1 more source

Home - About - Disclaimer - Privacy