Results 161 to 170 of about 4,474 (198)

Fully endovascular management of late pseudoaneurysm after aortic coarctation repair using graft sealing and coarctation occlusion. [PDF]

open access: yesJ Vasc Surg Cases Innov Tech
San Ginés Bahíllo E   +3 more
europepmc   +1 more source

Comparison of the Occlutech® Figulla® Septal Occluder and Amplatzer® Septal Occluder for Atrial Septal Defect Device Closure

Pediatric Cardiology, 2015
The Occlutech(®) Figulla(®) septal occluder (OFSO) is a later-generation double-disk device with few reports of its success rates and complications compared with the Amplatzer(®) septal occluder (ASO), which is the worldwide standard device in percutaneous atrial septal defect (ASD) closure. We recruited and compared the results in 149 patients (76.5 %
Worakan Promphan   +1 more
exaly   +3 more sources

Embolized Amplatzer septal occluder device presenting with ventricular fibrillation

Cardiovascular Revascularization Medicine, 2011
The Amplatzer septal occluder device is used with high success and low-complication rate. Device embolization occurs in around 0.3-0.55% of cases. We report the case of a 44-year-old man with ventricular fibrillation (VF) due to embolization of Amplatzer septal occluder into the right ventricle, 1 h after the successful closure of secundum ASD with a ...
Orhan Ozer   +2 more
exaly   +3 more sources

Successful thrombolytic treatment of a mobile thrombus on atrial septal defect occluder device

open access: yesActa Clinica Belgica, 2016
This case report presents a case with septal occluder device thrombosis which was successfully treated with low dose longer duration of thrombolytic application.
Taner Sen   +2 more
exaly   +2 more sources

Patent foramen ovale with complex anatomy: Comparison of two different devices (Amplatzer Septal Occluder device and Amplatzer PFO Occluder device 30/35)

open access: yesInternational Journal of Cardiology, 2019
Background: Patent foramen ovale (PFO) closure after a cryptogenic cerebral ischemic event is a routinely procedure. The most used device is AmplatzerTM PFO Occluder 25 mm, but PFOs with complex anatomy require larger device for closure.
Mario Giordano   +2 more
exaly   +2 more sources

A new method of tracheoesophageal fistula treatment: Using an atrial septal defect occluder device for closure—The first Turkish experience

open access: yesGeneral Thoracic and Cardiovascular Surgery, 2018
ObjectiveOne of the techniques used in the treatment of tracheoesophageal fistula is applying the umbrella catheter, designed for closure of atrial septal defects, in this region. In the literature, we have encountered only 9 case reports in this regard.
Hasan Ersöz, Cem Nazli
exaly   +2 more sources

Erosion of an Amplatzer Septal Occluder Device Into the Aortic Root

The Annals of Thoracic Surgery, 2011
Atrial septal defects can be closed surgically or percutaneously. We report a patient who underwent percutaneous closure of an atrial septal defect with an Amplatzer septal occluder device (AGA Medical Corp, Golden Valley, MN). The patient presented 4 months later with congestive heart failure secondary to an erosion of the Amplatzer septal occluder ...
Abdallah, Kamouh   +3 more
openaire   +2 more sources

Surgical Removal of Embolized Ventricular Septal Occluder Device

World Journal for Pediatric and Congenital Heart Surgery, 2016
Ventricular septal defect (VSD) with valvar pulmonary stenosis (PS) is a combination of cardiac defects for which treatment by means of percutaneous catheter-directed intervention is sometimes considered. Septal occluder device embolization is a rare but potentially dreadful complication.
Nikunj, Vaidhya   +4 more
openaire   +2 more sources

Home - About - Disclaimer - Privacy