Results 21 to 30 of about 3,932 (298)
Service Life Prediction of Precast Concrete Structures Exposed to Chloride Environment
Chloride-induced corrosion is widely accepted as one of the primary causes of premature deterioration for concrete structures in marine or deicing salt environment.
Dawei Zhang +3 more
doaj +1 more source
Serviceability limit state and vibrations
Rad se sastoji od teorijskog i praktičnog dijela. U radu su prvo teorijski obrađena granična stanja konstrukcije, odnosno granično stanje nosivosti (GSN) i granično stanje uporabljivosti (GSU), pri čemu je poseban naglasak stavljen na problem vibracija ...
Jelić, Lucija
core +1 more source
Comprehensive system limit state function model and its application for CRTS II track slab
Considering safety and serviceability simultaneously, a comprehensive system limit state function (LSF) model and its application for CRTS II track slab is analyzed.
Xuan-Yi Zhang +3 more
doaj +1 more source
The experimental results for service load of sixteen simply supported two way reinforced concrete slabs under the action of concentrated patch load were determined based on the amount of permissible deflections and the crack widths.All the slabs had the ...
Sayhood Eyad, Ali Ammar, Sharhan Zahraa
doaj +1 more source
Experimental Investigation of Corrosion Cracking in Reinforced Concrete Beams Containing Nano Wollastonite [PDF]
Cracking of the concrete cover due to corrosion is defined as the serviceability limit state of reinforced concrete structures. This study evaluated the influence of a mineral admixture i.e.
Mahmoud Miri +2 more
doaj +1 more source
The lateral vibration serviceability of slender footbridges has been the subject of many studies over the last few decades. However, in spite of the large amount of research, a common criterion has not been set yet.
Rocío G. Cuevas +3 more
doaj +1 more source
This paper’s main aim was to explain the process of characterising the structural over-strength factor (R), seismic behaviour factor (Q), and the effective elastic stiffness, Keff, of cantilever-reinforced concrete (RC) urban bridge columns with solid ...
Sergio Márquez-Domínguez +5 more
doaj +1 more source
Reliability of stainless steel frames designed using the Direct Design Method in serviceability limit states [PDF]
Steel structures can be consistently and efficiently designed using system-based design-by-analysis approaches such as the Direct Design Method. However, since direct design approaches lead to potentially lighter structural configurations, they can also ...
Kim J.R. Rasmussen +4 more
core +1 more source
Serviceability limit state assessment of semi-submersible floating wind turbines [PDF]
The design of a floating wind turbine (FWT) should satisfy the serviceability limit state (SLS) requirement for an efficient and safe operation throughout the entire work life.
Moan, Torgeir, Wang, Shuaishuai
core
Structural design of concrete to EC2 and GB50010-2010: a comparison
We mainly compares the differences and similarities in the design using the Chinese code GB50010-2010 (modified in 2015) and Eurocode 2. The paper focuses on the comparison of the two design codes in relation to the ultimate limit state (ULS) and ...
Guo Yida +3 more
doaj +1 more source

