Results 111 to 120 of about 1,893,085 (303)
Background: Low-flow, low-gradient aortic stenosis with reduced left ventricular ejection fraction is a heterogeneous condition with challenging severity assessment.
Anıl Avcı +6 more
doaj +1 more source
ABSTRACT Background Quantitative Flow Ratio (QFR) is a well‐established, non‐hyperemic, angiographic, wire‐free predictor of ischemia when compared to Fractional Flow Reserve (FFR). However, its diagnostic accuracy at low frame rates (< 10 frames/second), commonly used in contemporary practice to minimize radiation exposure, has not been evaluated ...
Joseph M. O'Brien +13 more
wiley +1 more source
ABSTRACT Background Despite recommendations in international guidelines, Intracoronary pressure wire assessment (PWA) utilization remains limited in clinical practice. This study aims to describe (i) trends of PWA during Percutaneous coronary interventional (PCI), (ii) factors that predict its application, and (iii) association with in‐hospital ...
Hussein Bashar +3 more
wiley +1 more source
Quadricuspid aortic valve: a rare cause of aortic regurgitation and stenosis
Quadricuspid aortic valve is a rare congenital condition that occurs not only as an isolated anomaly, but also with other cardiac defects. We describe a 10-year-old boy whose aortic stenosis was diagnosed during infancy.
Selman Vefa Yildirim +3 more
doaj
Aortic Stenosis in Homozygous Familial Hypercholesterolemia
Background: Homozygous familial hypercholesterolemia (HoFH) is a rare genetic disorder characterized by extreme elevations in low-density lipoprotein cholesterol levels and premature cardiovascular disease.
Armen Erzingatzian, BSc +27 more
doaj +1 more source
Severe aortic valve stenosis in the elderly: high prevalence of sleep-related breathing disorders
Stefanie Keymel,1 Katharina Hellhammer,1 Tobias Zeus,1 Marc Merx,2 Malte Kelm,1 Stephan Steiner3 1Department of Cardiology, Pneumology, and Vascular Diseases, Medical Faculty, Heinrich Heine University Düsseldorf, Düsseldorf, 2Department of ...
Merx M +5 more
core
ABSTRACT Background Transcatheter aortic valve implantation (TAVI) with the Acurate Neo has been linked to a significant incidence of paravalvular leakage (PVL), addressed by the Acurate Neo 2 incorporating an active sealing skirt. Recent findings suggest that midframe under‐expansion is associated with worse outcomes.
Lisa Crusius +9 more
wiley +1 more source
Physiology‐Guided Drug‐Coated Balloon Angioplasty: What We Know and What is Yet to be Understood
Catheterization and Cardiovascular Interventions, EarlyView.
Marco Frazzetto +4 more
wiley +1 more source
ABSTRACT Background Transcatheter patent ductus arteriosus (PDA) device closure is an effective treatment option for premature infants with hemodynamically significant PDA. Left pulmonary artery (LPA) stenosis has been reported as a complication, however there is limited data on risk factors, clinical significance, and long‐term outcomes.
Bryan Mosher +7 more
wiley +1 more source
Exercise echocardiography in severe asymptomatic aortic stenosis. [PDF]
peer reviewedThe management of asymptomatic patients with severe aortic stenosis is challenging. Unfortunately, evaluation of symptoms such as dyspnoea remains subjective.
Donal, Erwan +7 more
core +1 more source

