Results 31 to 40 of about 3,265 (186)

Combination of Non-contact and Contact Measuring Methods for Analyzing Structural Conditions of Dry Transformers

open access: yesMeasurement Science Review, 2023
The article describes the non-contact and contact analysis of 1-MVA dry power transformers with epoxy-resin insulation using an acoustic camera and frequency analyzer with automatic sweeping for low-middle frequency areas.
Gutten Miroslav   +6 more
doaj   +1 more source

Casos de estudio de diagnóstico por SFRA a dos transformadores de potencia de tres devanados

open access: yesRevista Científica de Ingeniería Energética, 2022
El diagnóstico de los transformadores ha sido un tema al que se ha prestado mucha atención debido a la importancia que reviste en el fin de aumentar el tiempo de vida y la calidad de la explotación de los mismos.
Orestes Hernández Areu   +3 more
doaj  

Joint Energy Efficient and QoS-aware Path Allocation and VNF Placement for Service Function Chaining

open access: yes, 2018
Service Function Chaining (SFC) allows the forwarding of a traffic flow along a chain of Virtual Network Functions (VNFs, e.g., IDS, firewall, and NAT).
Akbari, Behzad   +4 more
core   +1 more source

Bringing Home the Bacon: A Case for Applying the New Jersey Urban School Funding Remedy from Abbott v. Burke to Poor Rural School Districts [PDF]

open access: yes, 2012
In 1997, seventeen poor rural school districts in New Jersey filed a lawsuit seeking a declaration that their districts were in violation of its students’ state constitutional right to a "thorough and efficient" education, and a financial remedy akin to ...
Gruber, Kyle E.
core   +2 more sources

Sweep frequency response analysis of three-phase induction motors using high frequency circuit model

open access: yese-Prime: Advances in Electrical Engineering, Electronics and Energy
Three-phase induction motor (TPIM) is one of the most important and expensive component in many industries. If a failure happens in service, the impact can be far reaching. Resulting in prolonged downtimes and expensive repairs.
Rizwanullah Khan   +4 more
doaj   +1 more source

Analysis of Transient Actions Influence in Power Transformer

open access: yesAdvances in Electrical and Electronic Engineering, 2011
This article is focused on the theory of unacceptable effect on transformer winding, mainly the overvoltages and the mechanical forces. In the next part of the article is described the measurement of selfdischarging voltage frequency dependence on ...
Josef Jurcik   +2 more
doaj   +1 more source

Modeling and Rotation Control Strategy for Space Planar Flexible Robotic Arm Based on Fuzzy Adjustment and Disturbance Observer

open access: yesMathematics
In precise space operation tasks, the impact of disturbing torques on the space flexible robotic arm (SFRA) cannot be ignored. Besides, the slender structure of the SFRA is very likely to generate vibration of the robotic arm.
Jiaqi Liu   +4 more
doaj   +1 more source

In Vitro Antimicrobial Activity and In Vivo Intestinal Barrier Regulation by Commiphora leptophloeos Bark Extract in 5‐Fluorouracil–Induced Mucositis

open access: yesChemistry &Biodiversity, Volume 23, Issue 4, April 2026.
ABSTRACT This study evaluated the phytochemical composition, antimicrobial activity, and in vivo protective effects of the hydroethanolic extract from Commiphora leptophloeos stem bark (HECL) against 5‐fluorouracil (5‐FU)‐induced intestinal mucositis. Despite the extensive traditional use of C.
Stphannie Jamyla de Araújo Barbosa   +17 more
wiley   +1 more source

Theoretical considerations while applying sweep frequency response analysis method in determining the interwinding capacitance of power transformers at higher frequencies

open access: yesEngineering Reports, Volume 1, Issue 2, September 2019., 2019
This paper systematically investigates on theoretical and practical aspects of frequency response analysis method in evaluating the dielectric integrity of transformers. Current practices focus on interwinding capacitances as they contain sensitive diagnostic information of transformer windings, magnetic core, and insulation.
Saravanakumar Arumugam
wiley   +1 more source

Frequency and time fault diagnosis methods of power transformers

open access: yesMeasurement Science Review, 2018
The authors describe experimental and theoretical analyses of faults of power transformer winding. Faults were caused by mechanical effect of short-circuit currents. Measurements of transformer were carried out in high-voltage laboratory.
Gutten Miroslav   +5 more
doaj   +1 more source

Home - About - Disclaimer - Privacy