Results 271 to 280 of about 14,553 (293)
Some of the next articles are maybe not open access.
P4J-3 Dip-Type Liquid-Phase Sensor Using SH-SAW
2007 IEEE Ultrasonics Symposium Proceedings, 2007This paper describes an SH-SAW based sensor device which can be directly dipped into a liquid. The sensor device is composed of a two-channel SH-SAW delay line on a 36Y-X LiTaO3. Those IDTs are surrounded with epoxy walls with a 50 mum height and a 160 mum thickness.
T. Kogai, H. Yatsuda, S. Shiokawa
openaire +1 more source
Investigation of SH-SAW sensors for toxic heavy metal detection
2013 IEEE SENSORS, 2013In this study, a guided shear horizontal mode surface acoustic wave (SH-SAW) sensor with 64° YX-LiNbO3 based piezoelectric substrate and gold (Au) interdigitated electrodes (IDE) was used for the detection of toxic heavy metal compounds. A flow cell, with a reservoir volume of 3 μl, which employs inlet and outlet valves for the microfluidic chamber and
Zeinab Ramshani +4 more
openaire +1 more source
Liquid sensing system based on two port SH-SAW resonator
1999 IEEE Ultrasonics Symposium. Proceedings. International Symposium (Cat. No.99CH37027), 1999A new liquid flow sensing system constructed with SH-SAW resonator was used to characterize liquid properties. Surface acoustic waves with the shear horizontal displacement (SH-SAW) have been used for sensing the properties in liquid phase. The SH-SAW resonator having two port was fabricated on a 36° rotated Y cut X prop. LiTaO3 (36YX LiTaO3) substrate.
T. Nomura +3 more
openaire +1 more source
Numerical analysis of liquid-phase SH-SAW biosensor on quartz
2012 IEEE International Ultrasonics Symposium, 2012This paper describes a numerical analysis for the shear horizontal surface acoustic wave (SH-SAW) immunoassay biosensor. A numerical calculation method which was proposed by Campbell and Jones has been generally used to calculate SAW propagation characteristics.
Mikihiro Goto +2 more
openaire +1 more source
Velocity and damping of the SH-SAW in normal liquid
Physica B: Condensed Matter, 2003Abstract We developed a shear horizontal surface acoustic wave (SH-SAW) sensor to investigate the viscoelastic properties and the transverse sound in normal and superfluid 3 He . The SAW was generated and detected by two sets of interdigital transducers on LiTaO3 substrate. The distance between generator and detector was 21 mm . The
Y. Aoki +5 more
openaire +1 more source
Temperature stability analysis of LGS for SH-SAW sensor applications
2010 IEEE International Frequency Control Symposium, 2010New piezoelectric materials such as Langasite (La 3 Ga 5 SiO 14 , LGS), are of particular interest for bio-chemical sensor applications because of their temperature compensated characteristics. For liquid phase sensing applications, acoustic devices operating in shear horizontal surface acoustic waves (SH-SAW) mode are desired due to their low wave ...
V. Carolina Ayala +3 more
openaire +1 more source
High coupling phononic SH-SAW resonators for in-liquid operation
2016 European Frequency and Time Forum (EFTF), 2016In this communication we report on initial studies on the in-liquid operation of surface acoustic wave (SAW) phononic resonators employing shear (SH)-SAWs. The mode of operation is a SH-SAW with very high electromechanical coupling, propagating in the X-direction of Y-cut LiNbO3 substrates.
V. Yantchev +3 more
openaire +1 more source
SH-SAW propagation in a piezoelectric structure with viscoelastic layer
2012 Symposium on Piezoelectricity, Acoustic Waves, and Device Applications (SPAWDA), 2012An analytical approach is taken to investigate shear horizontal surface acoustic wave propagation in viscoelastic/piezoelectric structure, where a viscoelastic material thin layer is bonded to a semi-infinite piezoelectric substrate. The analytical solution of dispersion relations are obtained for electrically open and shorted boundary conditions.
Jing Cui +3 more
openaire +1 more source
Rayleigh SAW-Assisted SH-SAW Immunosensor on X-Cut 148-Y LiTaO3
IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2016In this paper, we describe a shear horizontal surface acoustic wave (SH-SAW) immunosensor that utilizes induce agitation by a Rayleigh SAW (R-SAW) on an X-cut 148-Y LiTaO3 substrate. On this substrate, SH-SAWs and R-SAWs with different frequencies can be effectively generated at an interdigital transducer (IDT). First, to consider the power flow angles
Takashi Kogai +2 more
openaire +2 more sources
Optimization of gold film thickness for SH-SAW biosensor on quartz
2013 IEEE International Ultrasonics Symposium (IUS), 2013This paper describes a numerical analysis for the shear horizontal surface acoustic wave (SH-SAW) immunoassay biosensor. The numerical calculation method proposed by Campbell and Jones has generally been used to calculate SAW propagation characteristics.
Mikihiro Goto +2 more
openaire +1 more source

