Results 41 to 50 of about 423,321 (249)
Because of the limitations of testing facilities and techniques, the seismic performance of soil-structure interaction (SSI) system can only be tested in a quite small scale model in laboratory.
Zhenyun Tang +3 more
doaj +1 more source
The building mass damper (BMD) system, which incorporates the concept of a tuned mass damper into a mid-story isolation system, has been demonstrated as an effective system for suppressing structural vibration due to earthquakes. The BMD system separates
Pei-Ching Chen +3 more
doaj +1 more source
In the design of cold-formed steel (CFS) buildings, sheathings are used to provide lateral resistance to seismic or wind load. Many researchers have thoroughly studied the basic behavior of different sheathing (including walls sheathed with plywood ...
Yasser E. Ibrahim +5 more
doaj +1 more source
Shanghai International Design Center (SHIDC) is a hybrid structure of steel frame and reinforced concrete core tube (SF-RCC). It is a building of unequal height two-tower system and the story lateral stiffness of two towers is different, which may result
Deyuan Zhou +3 more
doaj +1 more source
The objective of this study is to examine a machine learning (ML) framework for calibrating the parameters of analytical models of complex nonlinear structural systems where experimental data is significantly limited.
Angela Lanning +2 more
doaj +1 more source
This report covers the following projects: Shake table tests of precarious rock methodology, field tests of precarious rocks at Yucca Mountain and comparison of the results with PSHA predictions, study of the coherence of the wave field in the ESF, and a
Anderson, John G. +6 more
core +2 more sources
Effect of Spacing and Slenderness Ratio of Piles on the Seismic Behavior of Building Frames
The general assumption of a rigid base at the bottom of building structures during analysis and design underestimates the seismic response. Building structures resting on loose sand and soft clayey soil are vulnerable to earthquake forces.
Joseph Antony Visuvasam +1 more
doaj +1 more source
Shake Table Tests on Infill Plasterboard Partitions [PDF]
Shaking table tests are performed to investigate the seismic behaviour of plasterboard partitions. A steel test frame is properly designed in order to simulate the seismic effects at a generic building storey. The tests are performed shaking the table simultaneously in both horizontal directions.
MAGLIULO, GENNARO +6 more
openaire +2 more sources
Seismic Response Effect on Base-Isolated Rigid Structures by Mass Eccentricity in Nuclear Plants
The purpose of this paper is to analyze the seismic response effect caused by the mass eccentricity of individual equipment when conducting base isolation for the improvement of the seismic performance of a nuclear power plant.
Tae-Myung Shin, Byung-Chan Lee
doaj +1 more source
Shake table tests of an industrial building
Shake table tests are conducted on a scaled frame model
of an industrial building, which has irregular story heights, different beam span lengths, and uneven weight distribution. Its elastic and inelastic responses are observed under simulated earthquakes.
Koichi Takanashi +2 more
openaire +1 more source