Results 61 to 70 of about 2,845 (94)
Bacterial bioluminescence for the real time and <i>in situ</i> monitoring of endoscope disinfection using plasma activated water. [PDF]
Northage N +5 more
europepmc +1 more source
Fusion strategy after odontoid fracture and three-column atlantoaxial displacement in a patient with prior C2-pelvis fusion: a case report. [PDF]
Patel P, McGinity M, Gragnaniello C.
europepmc +1 more source
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Bolted shear connectors in steel–concrete composite structures: Shear behavior
Structures, 2023The use of bolted shear connectors is of great importance to the sustainable development of steel–concrete composite structures. In this paper, an experimental program consisting of four push-out specimens is performed to investigate the effects of bolt length and fabrication method of concrete slabs on the shear behavior of single-nut embedded bolted ...
Xiaoyang Liu +9 more
openaire +2 more sources
Steel and Composite Structures, 2002
Perforated shear connectors currently used in composite steel and concrete structures are described and evaluated. Modifications of the perforated connector suitable for common use injavascript:confirm_mark(`abe`, `1`); civil and bridge engineering are proposed. The connectors were tested in laboratories of CTU Prague for shear load capacity.
Josef Machacek, Jiri Studnicka
openaire +1 more source
Perforated shear connectors currently used in composite steel and concrete structures are described and evaluated. Modifications of the perforated connector suitable for common use injavascript:confirm_mark(`abe`, `1`); civil and bridge engineering are proposed. The connectors were tested in laboratories of CTU Prague for shear load capacity.
Josef Machacek, Jiri Studnicka
openaire +1 more source
New Shear Connectors Based on PBL Shear Connector For Composite Arch Members
Structural Engineering International, 2014Perfobond Hoop (PBH) is a newly proposed shear connector based on the perfobond Leisten (PBL) connectors aiming at steel box–concrete composite sections for composite arch members, which has been p...
Liang Fan, Zhixiang Zhou
openaire +1 more source
Fatigue performance of bolted shear connectors
Australian Journal of Structural Engineering, 2021A computer-aided engineering (CAE) fatigue life prediction technique is developed in this paper to determine the fatigue strength of bolted shear connectors in composite structures.
Hosseini, Seyedeh M. (S33738) +2 more
openaire +2 more sources
Cyclic Performances of Shear Connectors
Composite Construction in Steel and Concrete VI, 2011Natural cyclic loads such as strong winds and earthquakes can cause changes in bending moment signs in composite structural elements. Consequently, the connectors will be subjected to alternate shear forces. For this reason, the cyclic behavior of shear connectors is particularly important in these loading conditions.
Adrian Liviu Ciutina, Aurel stratan
openaire +1 more source

