Results 151 to 160 of about 1,641,660 (340)
To investigate the shear performance of 16 m span prestressed hollow core slabs, shear tests were conducted on three pre-tensioned prestressed hollow core slabs with the same shear-to-span ratio.
Kang Zhao +5 more
doaj +1 more source
Fast‐acting hydrogel seals bleeding wounds as the illustrated injectable, pH‐responsive network rapidly gels in situ to stop hemorrhage, adhere strongly to wet tissue, and release antibiotics in a controlled, pH‐dependent manner. The material withstands high pressures, shows excellent biocompatibility, and degrades safely, offering a versatile platform
Arvind K. Singh Chandel +5 more
wiley +1 more source
A multilayered small‐caliber vascular scaffold combining electrospinning and 4‐axis printing is developed and biofunctionalized with marine sulfated polysaccharides from Holothuria tubulosa. The resulting construct exhibits enhanced hemocompatibility, tunable mechanical properties, and supports endothelial and smooth muscle cell adhesion and ...
Gabriele Obino +9 more
wiley +1 more source
This study presents the first entirely isogenic heart‐on‐chip, unifying cardiomyocytes, fibroblasts, and endothelial cells from a single iPSC source. The platform reveals a critical biological insight: the endothelium actively shields cardiac tissue from drug‐induced toxicity, challenging the predictive accuracy of conventional, avascular models for ...
Karine Tadevosyan +12 more
wiley +1 more source
An experimental investigation of retro-reinforced clay brick arches
This paper describes the laboratory testing of eight 2.95m span segmental profile clay brick arches. Seven of the arches were strengthened with longitudinal intrados (soffit) reinforcement; the eighth was left unreinforced as an experimental control ...
Ashour, AF, Chen, Y, Garrity, SW
core
Electrically Readable Lateral Flow Assay Using Organic Transistors for Diagnostic Applications
Electrolyte‐gated organic field‐effect transistors (EGOFETs) are integrated with lateral flow (LF) paper fluidics to create a reusable, portable, and low‐cost point‐of‐care (PoC) diagnostic test. The devices are validated for Human Immunoglobulin G detection, achieving high sensitivity (0.1 fm), selectivity, and reproducibility with rapid results in 20–
María Jesús Ortiz‐Aguayo +4 more
wiley +1 more source
Multiphase printable organohydrogels with tunable microstructures are developed to control molecular transport pathways for immiscible cargo. The tortuosity and domain size of the colloidal phases are tuned by adjusting temperature and shear during processing, which enables the tailoring of diffusion kinetics due to different transport pathways.
Riley E. Dowdy‐Green +4 more
wiley +1 more source
Spectral Tuning of Hyperbolic Shear Polaritons in Monoclinic Gallium Oxide via Isotopic Substitution
Spectral tuning of highly directional hyperbolic shear polaritons is realized via isotopic substitution of 16O to 18O in monoclinic β$\beta$‐phase gallium oxide. A red‐shift of almost 40 cm−1 is experimentally demonstrated with near‐field imaging, corroborated by the permittivity change extracted from far‐field experiments and density functional theory.
Giulia Carini +28 more
wiley +1 more source
Decoupling Dynamics and Crosslink Stability in Supramolecular Hydrogels Using Associative Exchange
How does reorganization impact the stability of supramolecular hydrogels? In contrast to dissociative crosslink exchange, implementing associative exchange in macroscale DNA hydrogels enables decoupling of reorganization dynamics from thermal and mechanical stability.
Pierre Le Bourdonnec +4 more
wiley +1 more source
Ionic epoxy networks are prepared using ammonium salts as hardeners, leading to a two‐stage curing process with a thermoplastic‐like intermediate. This uncommon behavior enables extrusion and fabrication of thermoplastic prepregs that can be cured into thermoset composites.
Izabela Kurowska +10 more
wiley +1 more source