Results 81 to 90 of about 179,621 (304)
SHALLOW FLAT SOFFIT PRECAST CONCRETE FLOOR SYSTEM [PDF]
A precast concrete floor system that eliminates the need for column corbels and beam ledges while being very shallow. The main advantages of the present system include a span to-depth ratio of 30, a flat soffit, economy, consistency with prevailing ...
Morcous, George, Tadros, Maher
core +1 more source
Cyclic behavior of a two-span RC beam built with plain reinforcing bars [PDF]
Reinforced concrete structural elements lacking appropriate seismic detailing and built with plain reinforcing bars, and subjected to cyclic loads like the ones induced by earthquakes, are particularly sensitive to the bond-slip mechanism.
Costa, Aníbal +3 more
core +3 more sources
Shear Performance of Horizontal Joints in Short Precast Concrete Columns with Sleeve Grouted Connections under Cyclic Loading. [PDF]
In this study, two short precast concrete columns and two cast-in-situ concrete columns were tested under cyclic loads. It was shown that the sleeve grouted connection was equivalent to the cast-in-situ connections for short columns when the axial ...
Bo Feng +4 more
doaj +1 more source
Sustainable Catalyst‐Free PLG Networks: Recyclability, Biodegradability, and Functional Performance
A catalyst‐additive free covalent adaptable network is developed from star‐shaped poly(lactide‐co‐glycolide) cross‐linked with pyromellitic dianhydride, enabling internal carboxylic acid‐driven transesterification. The resulting biodegradable network exhibits mechanical robustness (Young's modulus ≈1.6 GPa), complete recyclability, rapid biodegradation
Lars Schwarzer +2 more
wiley +1 more source
Analysis of FRP shear strengthening solutions for reinforced concrete beams considering debonding failure [PDF]
In this paper, a fiber beam model previously developed by the authors for the nonlinear analysis of strengthened elements, including the effects of shear, is used to predict the response of reinforced concrete (RC) beams strengthened in shear with fiber ...
Bairán García, Jesús Miguel +3 more
core +2 more sources
Tooth crown restoration was made in a complex system consisting of several elements, namely tensile strength and shear strength bond between copper alloy and acrylic resin after tin plating.
Endanus Harijanto, Sri Yogyarti
doaj +1 more source
Micro‐injection laser‐assisted bioprinting enables ultrafast and precise patterning of small endothelial cell spheroids by injecting a highly concentrated single‐cell suspension into GelMA/ColMA hydrogels. In co‐culture with fibroblasts, controlled pre‐vasculogenic network formation is obtained at microscale resolution.
Charles Handschin +9 more
wiley +1 more source
Thick Walled Multiple Opening Reinforced Concrete Conduits [PDF]
The Department of The Army Corps of Engineers, Engineering Division, Civil Works, Contract No.
Gamble, W.L. +3 more
core
The Design of a semi-prefabricated LVL-concrete composite floor [PDF]
This paper describes the design of a novel semi-prefabricated LVL-concrete composite floor that has been developed in New Zealand. In this solution, the floor units made from LVL joists and plywood are prefabricated in the factory and transported to the ...
Fragiacomo, Massimo, Yeoh, David
core +3 more sources
Bioprosthetic aortic valves have revolutionized the treatment of aortic stenosis, but their durability is limited by structural valve deterioration (SVD). This review focuses on the pericardial tissue at the heart of these valves, examining how its mechanical properties and calcification drive fatigue and failure.
Gabriele Greco +7 more
wiley +1 more source