Results 61 to 70 of about 39,899 (316)
Development of in-Core Neutron Fluence Rate Monitoring Device for Nuclear Reactor First Fuel Loading
To meet the requirements of safety control during the fuel loading and refueling of nuclear reactors, a reactor first loading monitoring system was developed, and the related mechanical structure and electrical structure design and manufacturing of the ...
LIU Yang;HE Gaokui;TIAN Huayang;ZHAO Jiangbin
doaj
Gradient-Type Magnetoelectric Current Sensor with Strong Multisource Noise Suppression
A novel gradient-type magnetoelectric (ME) current sensor operating in magnetic field gradient (MFG) detection and conversion mode is developed based on a pair of ME composites that have a back-to-back capacitor configuration under a baseline separation ...
Mingji Zhang, Siu Wing Or
doaj +1 more source
Improved ferrous shielding for flat cables [PDF]
To improve shielding of flat multicore cables, a thin, seamless ferrous shield around all cores optimizes low frequency magnetic shielding.
Drechsler, R. J.
core +1 more source
Light reflectance increases along incidence angle and transmittance significantly drops around 90‐degree incidence angle. Here, we report two‐photon laser printed micro mirrors that redirect the skimming light beam into normal light absorption. Using this technique, light‐driven micro walkers and grippers are demonstrated by using grazing incidence ...
Leilei Song, Jianfeng Yang, Hao Zeng
wiley +1 more source
An analysis of the electrostatic field of a cable twisted shielded pair for various types of test voltage: symmetric bipolar, unipolar and asymmetric is carried out.
A.V. Bezprozvannych, A.G. Kyessaeyv
doaj
A transparent dual‐network strain sensor integrates robust mechanical properties, room‐temperature self‐healing, and stable performance under sub‐zero conditions and prolonged storage. Its excellent biocompatibility and antimicrobial properties enable safe skin contact.
Wenqing Chen +8 more
wiley +1 more source
Shielding effectiveness of single conductor flat shielded cables [PDF]
The shielding effectiveness of single conductor shielded flat cables was studied to determine if shield and conductor geometry changes could reduce shield leakage. Common cable defects were also evaluated to establish their effect on shield effectiveness.
openaire +2 more sources
The EXO-200 detector, part I: Detector design and construction
EXO-200 is an experiment designed to search for double beta decay of $^{136}$Xe with a single-phase, liquid xenon detector. It uses an active mass of 110 kg of xenon enriched to 80.6% in the isotope 136 in an ultra-low background time projection chamber ...
Auger, M. +80 more
core +1 more source
Bioinspired Adaptive Sensors: A Review on Current Developments in Theory and Application
This review comprehensively summarizes the recent progress in the design and fabrication of sensory‐adaptation‐inspired devices and highlights their valuable applications in electronic skin, wearable electronics, and machine vision. The existing challenges and future directions are addressed in aspects such as device performance optimization ...
Guodong Gong +12 more
wiley +1 more source
Estimation Method of Metallic Sheath Current of High-Voltage Power Cables Based on Field Data
Sheath current is a critical indicator for defect diagnosis in the metallic sheath grounding system of high-voltage single-core shielded power cables. In practical engineering, the absence of precise cable electric and structural parameters and layout ...
Junping Cao +7 more
doaj +1 more source