Results 221 to 230 of about 30,106 (301)

Multilayered Digital Microfluidic Chip for Cell‐Based Assays

open access: yesAdvanced Materials Interfaces, EarlyView.
A multilayered digital microfluidic (mDMF) chip architecture is introduced to improve throughput and robustness in cell‐based assays. By multilayering electrode components and dielectric layers on glass, this design significantly reduces actuation voltage, maintains reliability, and enables expansion of the operational area with minimum current leakage.
Mert Ozden   +2 more
wiley   +1 more source

Ti3C2Tx MXene/Silver Composite Foams For Lightweight, High‐Performance Electromagnetic Interference Shielding and Joule Heating

open access: yesAdvanced Materials Interfaces, EarlyView.
Ultrathin MXene/EMF composite foams achieve a specific shielding efficiency of 749.6 dB.dB·cm3$\mathrm{dB}\cdot {\mathrm{cm}}^{3}$/g, while the silver‐enhanced MXene/Ag/EMF reaches 81.4 dB shielding effectiveness at just 1.0 mm thickness. Both composites exhibit rapid Joule heating, retain stability up to 250∘C$^\circ{\rm C}$, and withstand 1000 ...
Abdullah A. Mahmood   +7 more
wiley   +1 more source

Facet‐Specific PbS Quantum Dot Passivation Using Halide Perovskites for SWIR Photodetectors

open access: yesAdvanced Materials Interfaces, EarlyView.
PbS quantum dots (QDs) are emerging as powerful short‐wave infrared photodetectors, yet the passivation mechanism of large QDs by perovskites ‐ critical for their stability ‐ remains unexplained. Here, we unveil the ligand structure of CH3NH3PbI3 (MAPI)‐passivated 4‐nm PbS QDs using FTIR, XPS, SEM, NMR, and DFT.
L. Paillardet   +13 more
wiley   +1 more source

Shadow‐Free Back‐Contact Perovskite Thin‐Film Detectors for Direct Extreme‐Ultraviolet and Soft X‐Ray Sensing

open access: yesAdvanced Materials Interfaces, EarlyView.
A triple‐cation perovskite detector with a quasi‐interdigitated back‐contact architecture enables highly sensitive and linear EUV/soft x‐ray detection by minimizing electrode shadowing and enhancing charge extraction. Efficient interfacial carrier collection and rapid temporal response highlight the potential of back‐contact‐engineered perovskites for ...
Jingying Liu   +5 more
wiley   +1 more source

Flexible Chemiresistive Chitosan‐Glycerol Sensors on Laser‐Induced Graphene Electrodes for Room‐Temperature Ammonia Detection

open access: yesAdvanced Materials Technologies, EarlyView.
Flexible Chitosan‐glycerol sensor integrated with porous laser‐induced graphene (LIG) electrodes enable room‐temperature chemiresistive detection of ammonia (NH3) and proof‐of‐concept detection of fish spoilage. ABSTRACT We report a metal‐free sensor platform combining laser induced graphene (LIG) electrodes with drop‐deposited, glycerol‐plasticized ...
Mintesinot Tamiru Mengistu   +9 more
wiley   +1 more source

Benchmarking Coaxial and Angular Optical Emission Spectroscopy With Recommendations for Reliable Compositional In Situ Monitoring During Laser Powder Bed Fusion

open access: yesAdvanced Materials Technologies, EarlyView.
ABSTRACT Real‐time insight into local chemistry is critical for reliable part quality in additive manufacturing, especially laser powder bed fusion (PBF‑LB/M), where rapid thermal cycles and localized evaporation can undermine part performance. Optical emission spectroscopy (OES) offers non‑intrusive, in situ plume monitoring, but detection geometry ...
Philipp Gabriel   +4 more
wiley   +1 more source

Recent Advances of Slip Sensors for Smart Robotics

open access: yesAdvanced Materials Technologies, EarlyView.
This review summarizes recent progress in robotic slip sensors across mechanical, electrical, thermal, optical, magnetic, and acoustic mechanisms, offering a comprehensive reference for the selection of slip sensors in robotic applications. In addition, current challenges and emerging trends are identified to advance the development of robust, adaptive,
Xingyu Zhang   +8 more
wiley   +1 more source

Topography‐Regulated Screening Platform for Myoblast Contact Guidance

open access: yesAdvanced Materials Technologies, EarlyView.
This study develops a topography‐regulated screening platform (12 gradients in 96‐topography‐well plate) enabling analysis of skeletal muscle morphogenesis. The topography‐induced cell morphology changed, cell polarization, and myotube differentiation, establishing an evaluative framework for generating pathologically relevant myotube phenotypes to ...
Tianqi Feng   +6 more
wiley   +1 more source

Home - About - Disclaimer - Privacy