Results 261 to 270 of about 83,391 (283)
Some of the next articles are maybe not open access.

An Adjustable Sensorless Shoot-Through Protection for H-Bridges

IECON 2018 - 44th Annual Conference of the IEEE Industrial Electronics Society, 2018
The converters relying on H-bridge configurations exhibit complementary “symmetrical” switching devices for which a triggering dead-time must be considered in order to prevent shoot-through faults. There are two ways in which such dead-time is usually added to the bridges' input signals; namely, from the switching program itself, and by using dedicated
Luis Ibarra, Pedro Ponce, Arturo Molina
openaire   +1 more source

IGBT half-bridge shoot-through characterization for model validation

IAS '96. Conference Record of the 1996 IEEE Industry Applications Conference Thirty-First IAS Annual Meeting, 2002
A circuit is described for making a variety of measurements on half-bridge insulated gate bipolar transistor (IGBT) pairs for validating IGBT models. The circuit incorporates two robust isolated gate drives for the IGBTs. Each IGBT is driven with an eight-cycle square-wave burst with a long dead-time between bursts so that heat-sinking requirements are
D.W. Berning, A.R. Hefner
openaire   +1 more source

Potential to prevent mass shootings through domestic violence firearm restrictions

Criminology & Public Policy, 2019
Research SummaryWe investigated the extent to which the 89 mass shooters who committed their acts from 2014 through 2017 were known or suspected to commit domestic violence prior to the shooting, whether they had been engaged in the justice system in a way that could have led to domestic violence firearm restrictions, and why they were either not ...
April M. Zeoli, Jennifer K. Paruk
openaire   +1 more source

A shoot-through protection scheme for converters built with SiC JFETs

2009 IEEE Energy Conversion Congress and Exposition, 2009
SiC JFET has been an attractive device for the converter construction due to its superior switching performance and high temperature operation capability. But the shoot-through protection remains a challenge because of the limited knowledge and normally-on characteristics of this device. This paper presents a novel shoot-through protection approach.
null Rixin Lai   +3 more
openaire   +1 more source

A Doubly Grounded Transformerless PV Grid-Connected Inverter Without Shoot-Through Problem

IEEE Transactions on Industrial Electronics, 2021
As conventional transformerless PV grid-connected inverters have shoot-through problem and common mode leakage current issue, a doubly grounded transformerless PV grid-connected inverter is proposed. The proposed inverter consists of a buck converter and a buck–boost converter, which operates at positive and negative half-line cycles, respectively ...
Zhilei Yao, Yubo Zhang
openaire   +1 more source

Shoot through time-based controlled pulse generation for Z-source inverter

Australian Journal of Electrical and Electronics Engineering, 2017
AbstractDue to higher fluctuation and frequent shutdown of the power supplies, the inverter circuit operates successfully in the different application such as home appliances, renewable energyand conversion to provide the uninterrupted power supply.
B. Durai Babu, P. Murugesan
openaire   +1 more source

A Shoot-Through Protection Scheme for Converters Built With SiC JFETs

IEEE Transactions on Industry Applications, 2010
The SiC JFET is an attractive semiconductor device due to its superior switching performance and high-temperature operating capability. Its shoot-through protection remains a challenge due to the limited practical knowledge existent on this device and due to its inherent normally on nature.
Rixin Lai   +5 more
openaire   +1 more source

Data Organization of LED Bar Display Panel with Shoot-Through Connection

Chinese Journal of Liquid Crystals and Displays, 2011
Based on dual-color screen with 12 interfaces as an example,the unit circuit configu-ration of LED bar display panel was described.On this basis,the data organization of LED bar display panel was in-depth discussed when the data was horizontally shifting in the manner of shoot-through connection.In this paper,a display round was designed to lively ...
朱云芳 ZHU Yun-fang   +2 more
openaire   +1 more source

Performance Analysis of Shoot Through Control Approaches for Z-source Inverters

2019 4th International Conference on Power Electronics and their Applications (ICPEA), 2019
This paper aims to provide a full mathematical analysis and detailed comparison of four control strategies (SBC simple boost control, MBC maximum boost control, MCBC maximum constant boost control and MCBCth maximum constant boost control with third harmonic injection) developed for the purpose of controlling the Z-source inverters.
Ali TETA   +3 more
openaire   +1 more source

Active overcurrent protection schemes in bridge inverters operating under shoot-through conditions

2015 International Conference on Power, Instrumentation, Control and Computing (PICC), 2015
The following paper proposes two overcurrent protection schemes that are applicable for limiting the current through the main switching devices in Bridge type Inverters under shoot-through conditions. Under normal mode of operation, the high side and low side switches of the bridge converters conduct on alternate half cycles.
Anantha Keshava Irodi, N. R. Srinivas
openaire   +1 more source

Home - About - Disclaimer - Privacy