Results 11 to 20 of about 313,973 (156)

Short circuit transient power analysis of hybrid intrinsically safe circuit

open access: yesGong-kuang zidonghua, 2023
Currently, research on the intrinsically safe features of intrinsically safe circuits mostly relies on the IEC spark experimental device as the experimental platform.
NIE Honglin   +6 more
doaj   +1 more source

ОСОБЕННОСТИ ТРЕХМЕРНОГО МОДЕЛИРОВАНИЯ ЭЛЕКТРОМАГНИТНЫХ ПОЛЕЙ АСИНХРОННОГО ДВИГАТЕЛЯ

open access: yesElektrotehnìka ta Elektroenergetika, 2016
Цель. Разработка нового эффективного подхода для реализации трехмерной математической модели нестационарных электрических и магнитных полей в асинхронных двигателях с учетом их конструктивных особенностей, нелинейности электрофизических и магнитных ...
D. S. Yarymbash   +3 more
doaj   +1 more source

Fault response of grid-connected squirrel cage wind-power induction generator [PDF]

open access: yesPort Said Engineering Research Journal, 2014
This paper presents fault response of squirrel cage induction generator through grid connected of wind power. Thus, the Squirrel Cage Induction Generator (SCIG) is connected to an infinite bus through delta grounded wye transformer, transmission line and
Nagwa Fadi   +3 more
doaj   +1 more source

Improved efficiency of microcrystalline silicon thin film solar cells with wide band-gap CdS buffer layer [PDF]

open access: yes, 2017
In this paper, we have reported a new structure based upon an optical simulation of maximum light trapping and management in microcrystalline silicon thin film solar cells by using multi texture schemes and introducing an n-type cadmium sulphide (CdS ...
Charlton, Martin D.B.   +2 more
core   +5 more sources

АНАЛІЗ ГАРМОНІЧНОГО СКЛАДУ ЗМІННОГО МАГНІТНОГО ПОЛЯ, ПОВ’ЯЗАНОГО З ОБЕРТОВИМ РОТОРОМ ТУРБОГЕНЕРАТОРА, В РЕЖИМАХ НЕРОБОЧОГО ХОДУ ТА КОРОТКОГО ЗАМИКАННЯ

open access: yesElektrotehnìka ta Elektroenergetika, 2013
Подано чисельно-польовий метод розрахунку змінної складової магнітного поля на поверхні обертового ротора турбогенератора. Він заснований на багатопозиційних розрахунках магнітного поля з поворотами ротора і зміною струмів в обмотці статора. У фіксованих
V. I. Milykh, N. V. Polyakova
doaj   +1 more source

Comparative Analysis of High-Voltage Power Line Models for Determining Short-Circuit Currents in Towers Earthing Systems

open access: yesEnergies, 2021
The article deals with the problems of single-phase short-circuit current distribution in overhead power lines. Short-circuit disturbances cause many negative phenomena in power networks.
Rafał Tarko   +3 more
doaj   +1 more source

An independent axiomatisation for free short-circuit logic [PDF]

open access: yes, 2017
Short-circuit evaluation denotes the semantics of propositional connectives in which the second argument is evaluated only if the first argument does not suffice to determine the value of the expression.
Ponse, Alban, Staudt, Daan J. C.
core   +3 more sources

Distributed Dual Model for High-Frequency Transformer Windings: Electromagnetic Transients and Solid State Transformers

open access: yesIEEE Open Access Journal of Power and Energy, 2022
This paper presents a novel model for transformer windings to accurately represent the duality between electrical and magnetic circuits. The model can be used for the calculation of high-frequency transients in power systems and the design of high ...
Digvijay Deswal, Francisco De Leon
doaj   +1 more source

Investigation of Irreversible Demagnetization in Switched Flux Permanent Magnet Machines under Short-Circuit Conditions [PDF]

open access: yes, 2017
The irreversible magnet demagnetization phenomena are investigated in this paper , under both healthy and short - circuit conditions for a switched flux permanent magnet (SFPM) machine.
Gabsi, M.   +4 more
core   +3 more sources

Frequency and time fault diagnosis methods of power transformers

open access: yesMeasurement Science Review, 2018
The authors describe experimental and theoretical analyses of faults of power transformer winding. Faults were caused by mechanical effect of short-circuit currents. Measurements of transformer were carried out in high-voltage laboratory.
Gutten Miroslav   +5 more
doaj   +1 more source