Results 11 to 20 of about 15,696,238 (271)
Flexible direct current (DC) grid can realize large-scale renewable energy, wide-area coordinated complementation, and reliable power transmission. It is an important development that can be used to support high-voltage and large-capacity flexible DC ...
Yinfeng Sun +6 more
doaj +1 more source
A change-detection algorithm for short-circuit fault detection in closed-loop AC drives [PDF]
This paper deals with an on-line method for turn-to-turn short-circuit fault detection in low-voltage permanent-magnet synchronous machine drives. Due to the closed-loop control, the fault effects are reflected in the voltage.
Johan Gyselinck +10 more
core +1 more source
A large number of new energy units represented by wind power and photovoltaics are connected to the grid, making accurate calculation and verification of short-circuit current difficult. Given the phase mapping and the influence of electrical components (
QIAO Li +5 more
doaj +1 more source
Delay-line stabilized microwave oscillator with frequency control [PDF]
This thesis was submitted for the degree of Doctor of Philosophy and awarded by Brunel University.The technique whereby the frequency of an oscillator is stabilized using an external feedback network incorporating a delay-line is extended in this thesis ...
Free, Charles Edward
core +3 more sources
Influence of the line characterization on the transient analysis of nonlinearly loaded lossy transmission lines [PDF]
The analysis of nonlinearly terminated lossy transmission lines is addressed in this paper with a modified version of a method belonging to the class of mixed techniques, which characterize the line in the frequency domain and solve the nonlinear problem
PIGNARI, SERGIO AMEDEO +6 more
core +1 more source
. A method is proposed for calculating the initial value of the periodic term of the short- circuit strength of a dual-circuit overhead transmission line using multiphase replacement circuits. The method takes into account the electromagnetic connections
R. U. Galeeva +2 more
doaj +1 more source
Due to the low impedance of DC (Direct Current) power transmission line, short‐circuit current has a very high increment speed, which causes problems as difficulty in current limitation method.
Chaoran Zhuo +3 more
doaj +1 more source
Accurate and fast fault detection in transmission lines is of high importance to maintain the reliability of power systems. Most of the existing methods suffer from false detection of high-impedance faults.
Hamid Teimourzadeh +4 more
doaj +1 more source
Influence Mechanism and Suppression Control of the MMC on Short-Circuit Current Under AC Faults
Modular multilevel converter based high voltage direct current (MMC-HVDC) transmission systems may increase the short-circuit current and affect the AC fault clearing of circuit breakers.
Jian Yang +3 more
doaj +1 more source
Inductance calculation of submarine DC transmission line based on finite element analysis
[Objectives] Because of the characteristics of submarine direct current (DC) transmission cables, traditional circuit inductance calculation methods are unable to fit the system.
WANG Qi, YUAN Jiansheng, ZHAO Qiming
doaj +1 more source