Results 61 to 70 of about 15,696,238 (271)

Polynomial Chaos-Based Tolerance Analysis of Microwave Planar Guiding Structures [PDF]

open access: yes, 2011
This paper focuses on the derivation of an enhanced transmission-line model allowing to describe a realistic microwave interconnect with the inclusion of external uncertainties, like tolerances or process variations. The proposed method, that is based on
Paolo Manfredi   +3 more
core   +1 more source

Titanium Suboxides Responsible for Electronic Anomaly Near Room Temperature in the Ti3C2Tx MXene

open access: yesAdvanced Functional Materials, EarlyView.
Our multi‐technique study reveals that the near‐room‐temperature anomaly in Ti3C2Tx MXene is linked to titanium suboxide nanodomains, including Ti3O5, embedded within the MXene host. Their temperature‐driven transformation provides an alternative explanation to solvent‐ and swelling‐based models and offers new insight into the thermally activated ...
Bence G. Márkus   +8 more
wiley   +1 more source

Distance Protection for Outgoing Line of Photovoltaic Station Based on Superconducting Magnetic Energy Storage

open access: yesZhongguo dianli
Affected by the control strategy of photovoltaic inverters, the photovoltaic station has weak-feedback and current-phase-controlled characteristics.
Zhihui DAI   +4 more
doaj   +1 more source

High-speed simulation of PCB emission and immunity with frequency-domain IC/LSI source models [PDF]

open access: yes, 2003
Some recent results from research conducted in the EMC group at Okayama University are reviewed. A scheme for power-bus modeling with an analytical method is introduced.
Wang, Zhi Liang   +8 more
core   +1 more source

Historical Foundation and Practical Guideline for Ferroelectric Switching Kinetic Studies

open access: yesAdvanced Functional Materials, EarlyView.
The P and U pulses in the conventional PUND measurements are not identical because of the interplay between switching current and the measurement circuit components. This circuit effect can lead to a shift in polarization transients and misinterpreted physics in the switching kinetics.
Yi Liang, Pat Kezer, John T. Heron
wiley   +1 more source

Locating Fault on Transmission Line with Static Var Compensator Based on Phasor Measurement Unit

open access: yesEnergies, 2018
The flexible alternating current transmission systems (FACTS) have been widely used in modern power systems. Because of the presence of the FACTS devices, distance relays in transmission lines may inaccurately locate fault locations.
Ngo Minh Khoa, Doan Duc Tung
doaj   +1 more source

Double Circuit EHV Transmission Lines Fault Location with RBF Based Support Vector Machine and Reconstructed Input Scaled Conjugate Gradient Based Neural Network [PDF]

open access: yesInternational Journal of Computational Intelligence Systems, 2015
A new algorithm is developed to enhance the solution for the problems associated with double circuit transmission lines for the mutual coupling between the two circuits under fault conditions and which is highly variable in nature.
K. Gayathri, N. Kumarappan
doaj   +1 more source

Advances in Sustainable and Wearable Textile Based Soft Robotics

open access: yesAdvanced Functional Materials, EarlyView.
This Review examines advances in wearable textile‐based soft robotics, focusing on sustainable materials, integrated sensing, and scalable actuation. It discusses manufacturing and system integration across healthcare, assistive robotics, prosthetics, and human–machine interfaces, and highlights key challenges in circular design, including life‐cycle ...
Zahir Abbas   +6 more
wiley   +1 more source

Correlated Metal LaNiO3 as a p‐Type Transparent Conductor

open access: yesAdvanced Functional Materials, EarlyView.
p‐type transparent conducting oxides are needed to enable superstrate solar cell geometries with n‐type absorbers. The p‐type correlated metal LaNiO3 combines high optical transmission with low electrical resistivity and is compatible with a range of scalable deposition processes.
Shivang Beniwal   +8 more
wiley   +1 more source

Transient Voltage Distribution on the Single Phase Transmission Line under Short Circuit Fault Effect

open access: yes, 2018
Single phase transmission lines are used to transfer data or energy between two users. Transient conditions such as switching operations and short circuit faults cause the generation of the fluctuation on the waveform to be transmitted.
A. Kojah, A. Nacaroğlu
core   +1 more source