Results 41 to 50 of about 872,445 (297)

Analysis of influencing factors of short-circuit spark discharge in electric potential capacitance circuit

open access: yesGong-kuang zidonghua, 2020
Most of existing models and methods for research of capacitive circuit spark discharge and high-power intrinsic safety power supply only consider discharge characteristics of energy storage elements during discharge process, and do not consider influence
KANG Qian   +3 more
doaj   +1 more source

Features of fault transient's in generator network of powerful electric power stations

open access: yesИзвестия высших учебных заведений: Проблемы энергетики, 2021
THE PURPOSE. To consider the problems of generator circuit breaker. To consider the problems of high degree of asymmetry of short-circuit current and long delayed current zeros in detail. Propose methods for solving these problems. Develop the equivalent
E. P. Safonov, V. Ya. Frolov
doaj   +1 more source

A Scheme of DC-side Short-circuit Protection for Bi-directional Converterin Urban Rail Traction Power Supply System

open access: yesKongzhi Yu Xinxi Jishu, 2021
Using bi-directional converters for traction power supply in urban rail transit, traditional PWM rectifiers cannot meet the requirement of DC feeder protection for 27 kA short-circuit current with 120 ms continuous time.
WANG Xiong   +3 more
doaj  

Consistency evaluation of the current distribution of short-circuit tests in AT feeding systems for high-speed railways

open access: yesJournal of Modern Transportation, 2018
To improve the accuracy of fault location system, several short-circuit tests need to be conducted before being brought into service in autotransformer (AT) feeding systems for high-speed railways in China.
Qing-an Ma, Wei Liu
doaj   +1 more source

Transistor current and voltage limiting switch [PDF]

open access: yes, 1970
Limiting circuit protects the main power supply of electronic modules and limits the current drawn by each module should a short circuit occur. It limits current within one mA when used with direct current of either polarity, or with pulse or ac power ...
Hilbert, E. E.
core   +1 more source

Diversity and complexity in neural organoids

open access: yesFEBS Letters, EarlyView.
Neural organoid research aims to expand genetic diversity on one side and increase tissue complexity on the other. Chimeroids integrate multiple donor genomes within single organoids. Self‐organising multi‐identity organoids, exogenous cell seeding, or enforced assembly of region‐specific organoids contribute to tissue complexity.
Ilaria Chiaradia, Madeline A. Lancaster
wiley   +1 more source

Tumour–host interactions in Drosophila: mechanisms in the tumour micro‐ and macroenvironment

open access: yesMolecular Oncology, EarlyView.
This review examines how tumour–host crosstalk takes place at multiple levels of biological organisation, from local cell competition and immune crosstalk to organism‐wide metabolic and physiological collapse. Here, we integrate findings from Drosophila melanogaster studies that reveal conserved mechanisms through which tumours hijack host systems to ...
José Teles‐Reis, Tor Erik Rusten
wiley   +1 more source

Influence of Short‐Circuit Current Nonperiodic Component Increasing on Radial Dynamic Stability of Power Transformer Winding Under Reclosing

open access: yesIET Electric Power Applications
As one of the key main equipment of the power system, the transformer directly affects the safe and reliable operation of the system. In the process of transformer reclosing, the internal electromagnetic environment is obviously different from that of ...
Yuefeng Hao   +3 more
doaj   +1 more source

Design of high-power intrinsically safe power supply based on fault current change rate

open access: yesGong-kuang zidonghua, 2021
In order to solve the problems of low output power, poor protection effect, and slow dynamic response speed of existing intrinsically safe power supply, a high-power intrinsically safe power supply based on fault current change rate is designed.
KANG Qian   +3 more
doaj   +1 more source

Analisis Penggunaan Reaktor Pembatas Arus sebagai Pembatas Arus Hubung Singkat di PT Pulp And Paper [PDF]

open access: yes, 2015
To keep stability in power supply distribution, PT. Pulp and Paper used loop distribution system in their main substation. This thing caused possibilty of short-circuit current may exceed circuit breaker's capability.
Ervianto, E. '. (Edy)   +2 more
core  