Applying series braking resistors to improve the stability of low inertia synchronous generators [PDF]
Widely held concerns over the environmental impact of emissions from large fossil fuelled generating plants are serving to promote the connection of renewable or sustainable generation onto distribution networks.
Anaya-Lara, Olimpo +4 more
core
Simulation Research on Short-circuit Fault of Metro Drive System
In order to research the influence of short circuit fault for metro train traction system on safety performance of the power net, the detailed mathematical model was derived for the short circuit fault of metro in the traction line.
WANG Renqing +4 more
doaj
Power transformers, as critical components in regional power distribution and transmission systems, require early fault detection to ensure system reliability.
Chengbo Hu +6 more
doaj +1 more source
A Fault-Tolerant T-Type Multilevel Inverter Topology with Soft-Switching Capability Based on Si and SiC Hybrid Phase Legs [PDF]
The performance of a novel three-phase four-leg fault-tolerant T-Type inverter topology is presented in this paper, which significantly improves the inverter\u27s fault-tolerant capability regarding device switch faults.
Demerdash, Nabeel +4 more
core +1 more source
A slight turn‐to‐turn short‐circuit fault in the incipient stage does not trigger fuse protection, and the regular transmission and transformation functions of the transformer within the power grid are not affected very much by the incipient turn‐to‐turn
Si Chen +3 more
doaj +1 more source
Permanent magnet synchronous motors (PMSMs) play a crucial role in industrial production, and in response to the problem of PMSM turn-to-turn short-circuit and demagnetization faults affecting production safety, this paper proposes a PMSM turn-to-turn ...
Yinquan Yu +5 more
doaj +1 more source
Impact of system expansion on specification of personal protective equipment : arc flash analysis [PDF]
Electricity network expansion require the installation of new substations and switchgear equipment. This, in many cases, is intended to cater for electrical energy demand much needed for industrial operations.
core +1 more source
Short-Circuit Fault Detection and Classification Using Empirical Wavelet Transform and Local Energy for Electric Transmission Line. [PDF]
Huang N +7 more
europepmc +1 more source
Real-Time Zero-Sequence-Voltage Estimation and Fault-Tolerant Control for an Open-Winding Five-Phase Fault-Tolerant Fractional-Slot Concentrated-Winding IPM Motor Under Inter-Turn Short-Circuit Fault. [PDF]
Cui R, Ji Q, Zhang S, Li H.
europepmc +1 more source
Detection and Localization of Rotor Winding Inter-Turn Short Circuit Fault in DFIG Using Zero-Sequence Current Component Under Variable Operating Conditions. [PDF]
Aziz MS, Zhang J, Ruzimov S, Huang X.
europepmc +1 more source