Context Accurate intraocular lens (IOL) power calculation is mandatory to achieve satisfactory refractive outcomes. Axial length, keratometric readings, anterior chamber depth, and other measurements are utilized to estimate postoperative effective lens ...
Rafik M.F El-Ghazawy +3 more
doaj +3 more sources
Longitudinal assessment of optical quality and intraocular scattering using the double-pass instrument in normal eyes and eyes with short tear breakup time. [PDF]
PURPOSE: To assess the longitudinal changes in optical quality including intraocular scattering in normal eyes and eyes with short tear breakup time (TBUT).
Hidenaga Kobashi +4 more
doaj +4 more sources
Purpose To report the refractive outcomes of long (≥25.00 mm) and short (≤22.00 mm) axial length (AL) eyes undergoing immediately sequential bilateral cataract surgery (ISBCS). Methods In this retrospective cohort study, patients who underwent ISBCS were
André S. Pollmann +6 more
doaj +3 more sources
Accuracy of new intraocular lens calculation formulas in Chinese eyes with short axial lengths
PurposeTo compare the measurement accuracy of new/updated intraocular lens (IOL) power calculation methods, namely, Kane, Emmetropia Verifying Optical (EVO), with existing methods (Barrett Universal II, Olsen, Haigis, Hoffer Q, Holladay 1, SRK/T) in ...
Yueting Ma +4 more
doaj +3 more sources
Intraocular Lens Optic Power Calculation on “Short” Eyes. A Review
In recent years, due to advances in surgical technique, instruments and design of intraocular lenses (IOLs), patient expectations of cataract surgery have increased significantly, often matching those after refractive interventions.
K. B. Pershin +3 more
doaj +2 more sources
Meta‐analysis of accuracy of intraocular lens power calculation formulas in short eyes
Wu Jiang, Weirong Chen, Tiao Lin
exaly +2 more sources
BackgroundTo compare the accuracy of intraoperative wavefront aberrometry using the ORA VLynk system with different biometry-based formulas in short and long eyes after cataract surgery.MethodsThis prospective study considered 48 eyes with axial lengths ...
Pedro Tañá-Rivero +5 more
doaj +3 more sources
Influence of the anterior chamber depth on the accuracy of the intraocular lens optical power calculation in short eyes [PDF]
Background. The calculation of the optical strength of the intraocular lens (IOL) in eyes with a short anterior-posterior axis presents significant difficulties due to non-standard anatomical parameters of the eye, including the anterior chamber depth ...
Alexander Yu. Tsygankov +4 more
doaj +1 more source
PURPOSE To compare the accuracy of intraocular lens power calculation formulas and to examine the correlation of this exactness with the axial length for eyes shorter than 22.00 mm Methods: The data of hyperopic patients who underwent uneventful ...
W. Stopyra
semanticscholar +1 more source
Laboratory analyses of two explanted hydrophobic acrylic intraocular lenses
Two three-piece hydrophobic acrylic intraocular lenses (IOLs) were explanted from two patients at 7 and 9 years, respectively, after implantation, because of poor fundus visualisation and/or a clinically significant decrease in visual acuity related to ...
Yunhai Dai +3 more
doaj +1 more source