Results 111 to 120 of about 1,936,922 (167)
Frequency tunable magnetostatic wave filters with zero static power magnetic biasing circuitry. [PDF]
Du X +9 more
europepmc +1 more source
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Shunt Capacitor Bank Protection Methods
IEEE Transactions on Power Apparatus and Systems / Technical Operations Committee, 1982A "Guide for Protection of Shunt Capacitor Banks," ANSI/IEEE Standard C37.99-1980, has been prepared recently by the, Power System Relaying Committee to assist in the effective application of relays for the protection of shunt capacitor banks used in substations.
exaly +2 more sources
A Unique Multipurpose Damping Circuit for Shunt Capacitor Bank Switching
IEEE Transactions on Power Delivery, 1993Considerations on disturbances related to shunt capacitor bank (SCB) switching are summarized and a unique damping circuit which is able to cope with all of them is proposed. This damping circuit consists of a reactor in parallel with a resistor which is in series with a metal oxide varistor (MOV), the latter being used to switch on the resistor only ...
A. Sabot +6 more
exaly +2 more sources
Shunt Capacitor Bank Series Group Shorting (CAPS) Design and Application
IEEE Transactions on Power Delivery, 2001Summary form only given, as follows. This paper highlights results of a design study to optimize CAPS (CAPacitor bank series group Shorting) as applied to EHV and HV shunt capacitor banks. The study concluded that CAPS can be built from standard, commercially available components, and can have economic advantage over conventional shunt capacitor banks ...
C W Taylor, A Edris
exaly +2 more sources
On-Line Monitoring of Shunt Capacitor Bank Based on Relay Protection Device
In modern power systems, the installation of a shunt capacitor bank is one of the cheapest and most widely used methods for improving the voltage profile.
Yifeng Lin
exaly +2 more sources
Time-Domain Protection and Fault Location of Wye-Connected Shunt Capacitor Banks Using Superimposed Current and Differential Voltage [PDF]
This paper presents protection and fault location of wye-connected shunt capacitor banks used in medium or high voltage applications. The proposed method is sensitive to single element failure obtained by using voltage adaptive instantaneous superimposed
Ashok Kumar Pradhan, Rabindra Mohanty
exaly +2 more sources
Fault location in shunt capacitor banks
10th IET International Conference on Developments in Power System Protection (DPSP 2010). Managing the Change, 2010Shunt capacitor banks (SCBs) are used in the electrical industry for power factor correction and voltage support. Over the years, the purpose of SCBs has not changed, but as new dielectric materials came to market, the fusing practices for these banks changed from externally fused to internally fused, fuseless, and finally to unfused.
S. Samineni +3 more
openaire +1 more source
Switching High-Voltage Shunt Capacitor Banks
Transactions of the American Institute of Electrical Engineers, 1951ONE OF THE first 34.5-kv capacitor banks in this country was installed recently on the Indianapolis Power and Light Company system. This capacitor bank, totaling 7,290 kva, was part of a system program of adding reactive generation close to reactive load in the most practical and economical manner. See Figures 1 and 2.
A. W. Funkhouser +2 more
openaire +1 more source
A study of capacitor element failures in high voltage Shunt Capacitor Banks
2017 IEEE 30th Canadian Conference on Electrical and Computer Engineering (CCECE), 2017Internal failures in Shunt Capacitor Bank (SCB) units render trips from unbalance protection to prevent from further damage to the equipment. Fuseless and internally fused capacitor cans are the dominant technologies in power capacitor design, which do not provide external indication for units with failed elements.
Hessamoddin Jouybari-Moghaddam +1 more
openaire +1 more source
Methodology for Valuation of Shunt Capacitor Bank in Power Grid
2019 10th International Conference on Computing, Communication and Networking Technologies (ICCCNT), 2019At present there are no strict guidelines in routine to judge the deployment of capacitor banks in the grid and practicing loss reduction in real time is an iterative task, without any guaranteed results. Therefore, research work carried in this paper tries to provide a base to the system engineer for valuation of shunt capacitor bank in power grid ...
Nidhi Sharma +3 more
openaire +2 more sources