Results 51 to 60 of about 10,662,693 (288)

Converging language streams in the human temporal lobe [PDF]

open access: yes, 2006
There is general agreement that, after initial processing in unimodal sensory cortex, the processing pathways for spoken and written language converge to access verbal meaning.
Spitsyna, Galina   +9 more
core   +1 more source

Complementing Engel Classification: Postoperative Scalp EEG as an Objective Indicator in SEEG‐Guided Radiofrequency Thermocoagulation—A Seizure‐Onset Pattern‐Based Stratified Analysis—

open access: yesAnnals of Clinical and Translational Neurology, EarlyView.
ABSTRACT Background Stereoelectroencephalography‐guided radiofrequency thermocoagulation (SEEG‐RFTC) is a minimally invasive therapy for drug‐resistant focal epilepsy. However, the relationship between specific seizure‐onset patterns (SOPs), particularly low‐voltage fast activity (LVFA), and postoperative scalp EEG normalization remains inadequately ...
Yi‐qing Yang   +6 more
wiley   +1 more source

Array Antenna with Suppressed Side Lobe Level for Millimeter-Wave Applications

open access: yes, 2018
As millimeter-wave(mm-wave) band is attracted for 5G. and autonomous driving technology, mm-wave band has become a commercial interest. In mm-wave radar applications, the suppression of the side lobe level has to he considered thoroughly.
Hwang, In-June   +5 more
core   +1 more source

Linear Antenna Array Design with Dolph-Chebyshev Method for High Gain and Side-Lobe Reduction in Wireless Systems

open access: yesЖурнал нано- та електронної фізики
This paper presents a linear antenna array design employing the Dolph-Chebyshev method to achieve high gain while effectively minimizing side-lobe levels for IoT applications.
A. Srinag, S. Aruna, K. Srinivasa Naik
doaj   +1 more source

Synthesis of a Linear Antenna Array for Maximum Side-lobe Level Reduction

open access: yesInternational Journal of Computer Applications, 2014
are number of Techniques used to reduce Side Lobe Level (SLL) of antenna arrays to save power and improve Quality of Service (QoS) by ensuring maximum radiation in desired direction, several methods are available in literature. It is a well known fact that when an attempt is made to reduce the first sidelobe level of an antenna array, the beamwidth ...
K. Ahmad, D. D. Dajab, S. A.Babale
openaire   +1 more source

Review on Linear Array Antenna with Minimum Side Lobe Level Using Genetic Algorithm

open access: yes, 2018
Antenna array is formed by assembly of radiating elements in an electrical or geometrical configuration. In most cases the elements are identical. In this paper proposed a very simple and powerful method for the synthesis of linear array antenna and GA ...
Er. Praveen Kumar Patidar, Aditya Sharma
core   +1 more source

Incidence, Risk Factors and Management of Adverse Events in Contemporary Real‐World Care of Children with Juvenile Idiopathic Arthritis

open access: yesArthritis Care &Research, Accepted Article.
Objective We describe the frequency, risk factors, severity, and management of actionable and serious adverse events (AAE and SAE) in children with newly diagnosed Juvenile Idiopathic Arthritis (JIA) in Canada. Methods We enrolled patients within 3 months of JIA diagnosis in the Canadian Alliance of Pediatric Rheumatology Investigators (CAPRI) Registry,
Bashayer Alnuaimi   +10 more
wiley   +1 more source

Impact of aberrant cerebral perfusion on resting-state functional MRI: A preliminary investigation of Moyamoya disease. [PDF]

open access: yesPLoS ONE, 2017
The impact of chronic cerebral hypoperfusion on resting-state blood oxygen level-dependent signal fluctuations remains unknown. We aimed to determine whether chronic ischemia induces changes in amplitude of low-frequency fluctuations (ALFF) and to ...
Yituo Wang   +12 more
doaj   +1 more source

A Holistic Platform Approach for Developing Robust Pulmonary mRNA Delivery: Integrating Novel Phenolic Acid‐Derived Ionizable Lipids and Device Engineering

open access: yesAdvanced Functional Materials, EarlyView.
An integrated pulmonary mRNA delivery platform combining novel biodegradable syringic acid‐derived ionizable lipids, design‐of‐experiments formulation optimization, and vibrating‐mesh nebulizer engineering enabled stable aerosolization and efficient lung delivery.
Neha Kaushal   +21 more
wiley   +1 more source

Stabilization of Strongly Reduced Fe(I) Single Atom Species Coordinated in a 2D Self‐Assembled Metal–Organic Network

open access: yesAdvanced Functional Materials, EarlyView.
A graphene‐supported 2D metal–organic network stabilizes highly reactive Fe(I)‐N4 single sites through Co‐induced charge redistribution. Combined experiments and theory reveal Fe(I) formation, oxygen‐driven oxidation, and O2 activation mechanisms, offering a strategy to access low‐valent iron centers relevant to catalytic and biological processes ...
Alessandro Namar   +9 more
wiley   +1 more source

Home - About - Disclaimer - Privacy