Results 51 to 60 of about 1,648,508 (271)

Adoption of SIFT-MS for VOC Pollution Monitoring in South Korea

open access: yesEnvironments, 2023
The pollution of air and water with volatile organic compounds (VOCs), both hazardous and odorous, is of significant concern due to impacts on human health and quality of life, as well as the environment. South Korea is a highly industrialized and densely populated nation and suffers from significant VOC and ozone pollution.
Vaughan S. Langford   +3 more
openaire   +1 more source

The SIFT and FALP techniques; applications to ionic and electronic reactions studies and their evolution to the SIFT-MS and FA-MS analytical methods [PDF]

open access: yes, 2014
Flow tube reactors coupled with quantitative mass spectrometry have made, and continue to make, major contributions to gas phase ion–molecule chemistry, to recombination and electron attachment studies and, most recently, to gas phase trace gas analysis.

core   +1 more source

Identification of Corrosive Volatile Compounds Found in the Headspace of Chicken Noodle Soup Retorted in Metal Cans

open access: yesInternational Journal of Food Science, 2023
This study investigated the development of volatile compounds in the headspace of canned chicken noodle soup (and sought to develop appropriate testing methods).
Yajun Wu   +4 more
doaj   +1 more source

Effect of pH, Reducing Sugars, and Protein on Roasted Sunflower Seed Aroma Volatiles

open access: yesFoods, 2023
Sunflower seeds are a popular snack in many countries, such as the United States, China, and Spain. Sunflower seeds are typically roasted to create desirable aromas before being eaten.
Jessica Laemont, Sheryl Barringer
doaj   +1 more source

Headspace-Selected Ion Flow Tube Mass Spectrometry Workflows for Rapid Screening and Quantitation of Hazardous Volatile Impurities in Personal Care Products

open access: yesAnalytica
Personal care products (PCPs) are intended for regular application by consumers and therefore assuring the safety of these products is very important. Recently, benzene contamination has been highlighted in certain PCPs.
Mark J. Perkins   +2 more
doaj   +1 more source

Real-Time Phytoncide Monitoring in Forests: A Comparative Study of SIFT-MS and Conventional GC-MS Methods

open access: yes, 2023
Conventional gas chromatography-mass spectrometry (GC-MS) analysis methods for measuring the concentration of phytoncides in forests are limited because of the need for an extended human presence in forests, the risk of errors, and contamination.
Yeji Choi   +4 more
core   +1 more source

Increase of methanol in exhaled breath quantified by SIFT-MS following aspartame ingestion [PDF]

open access: yesJournal of Breath Research, 2015
Aspartame, methyl-L-α-aspartyl-L-phenylalaninate, is used worldwide as a sweetener in foods and drinks and is considered to be safe at an acceptable daily intake (ADI) of 40 mg per kg of body weight. This compound is completely hydrolyzed in the gastrointestinal tract to aspartic acid, phenylalanine and methanol, each being toxic at high levels.
Španěl, P. (Patrik)   +3 more
openaire   +3 more sources

RI-LPOH: Rotation-Invariant Local Phase Orientation Histogram for Multi-Modal Image Matching

open access: yesRemote Sensing, 2022
To better cope with the significant nonlinear radiation distortions (NRD) and severe rotational distortions in multi-modal remote sensing image matching, this paper introduces a rotationally robust feature-matching method based on the maximum index map ...
Huangwei Tu, Yu Zhu, Changpei Han
doaj   +1 more source

Real time analysis of breath volatiles using SIFT-MS in cigarette smoking [PDF]

open access: yesRedox Report, 2001
The selected ion flow tube mass spectrometry (SIFT-MS) technique enables real time analysis of trace volatiles at ppb levels without preconcentration steps or chemical derivatization. Most previous studies of trace compounds on the breath were analyzed using gas chromatography where enhanced detection sensitivity was achieved by concentrating the ...
S T, Senthilmohan   +4 more
openaire   +2 more sources

ssec/sift: Version 1.2.0

open access: yes, 2020
Pull Requests Merged Bugs fixed PR 296 - Update bundle scripts to handle installation directory being moved PR 293 - Fix HiDPI setting being set too late PR 292 - Fix bundle script having wrong permissions and activation path PR 288 - Fix STANDARD_NAME ...
k30n1   +8 more
core   +1 more source

Home - About - Disclaimer - Privacy