Ultra-Trace Real Time VOC Measurements by SIFT-MS for VIAQ
SAE International Journal of Engines, 2017<div class="section abstract"><div class="htmlview paragraph">Vehicle interior air quality (VIAQ) measurements are currently conducted using the offline techniques GC/MS and HPLC. To improve throughput, speed of analysis, and enable online measurement, specialized instruments are being developed.
Jennifer H. Zhu +6 more
openaire +1 more source
High‐Throughput Analysis of Fruit Ripening by SIFT‐MS
Lebensmittelchemie, 2021A. Ingendoh, M. Perkins, V. Langford
openaire +1 more source
Assessing SIFT-MS Method Feasibility (Procedure 1)
The marked difference in the analytical approach of SIFT-MS compared with the conventional GC and LC techniques means that the feasibility of method transfer – or new method development – for SIFT-MS should be evaluated prior to experimental work. Drawing on principles discussed in Part 1 of this book, this chapter describes a procedure by which the ...openaire +1 more source
Modifying an Existing SIFT-MS Method (Procedure 7)
SIFT-MS, with its chromatography-free, soft chemical ionisation approach to the analysis of volatile compounds requires different procedures for modifying validated test methods compared to GC. This chapter provides procedures for modifying SIFT-MS methods involving addition or removal of analytes, modification to product ion selections, a change of ...openaire +1 more source
Breath Collection Equipment for Clinical Applications with SIFT-MS Instruments
2006Real time detection of Volatile Organic Compounds (VOCs) using Selected Ion Flow Tube – Mass Spectrometry (SIFT-MS) provides a unique opportunity for research into breath testing for clinical diagnosis. However, before engaging in research into breath analytes as markers of disease, appropriate breath collection methods are required.
openaire +2 more sources
Preparing the Automated SIFT-MS Instrument for Analysis (Procedure 2)
Selected ion flow tube mass spectrometry (SIFT-MS) instruments have different operational procedures compared to conventional chromatographic instruments, since they are based on different principles. This chapter describes, in a general manner, how to prepare a SIFT-MS instrument for analysis, together with a coupled robotic autosampler. Additionally,openaire +1 more source
Validating SIFT-MS Analysis of Volatiles in Breath
Current Analytical Chemistry, 2013Malina Storer +3 more
openaire +1 more source
Measuring VOCs in Christchurch ambient air : using SIFT-MS technique
2002The project is aimed at monitoring the volatile organic compounds (VOCs) that may be regarded as undesirable in Christchurch's ambient air. Nine VOCs viz NH3 (ammonia), C2H4 (acetylene), C3H6OH (methanol), C2H5OH (ethanol), CH3CHO (acetaldehyde), C6H6 (benzene), C7H8 (toluene) and C8H10 (xylene) were-selected to be examined diurnally and seasonally ...
openaire +3 more sources
Application of SIFT-MS in Monitoring Volatile Compounds in Fruits and Vegetables
Current Analytical Chemistry, 2013Nutsuda Sumonsiri, Sheryl Barringer
openaire +1 more source
Advances in On-line Absolute Trace Gas Analysis by SIFT-MS
Current Analytical Chemistry, 2013Patrik Spanel, David Smith