SIFT-MS

Selected ion flow tube mass spectrometry (SIFT-MS) is a chromatography-free, direct-analysis technique that is ideally suited to real-time, quantitative analysis of volatile compounds in air at trace concentrations. SIFT-MS utilises highly controlled, soft chemical ionisation – in the form of gas-phase ion–molecule reactions – coupled with mass ...
Vaughan S. Langford, Mark J. Perkins
openaire   +1 more source

SIFT-MS: development of instrumentation and applications.

2007
Data is presented for a range of experiments that have been performed using a selected ion flow tube (SIFT) instrument operated at room temperature (~ 298K) with carrier gas pressures typically in the range of 0.3 – 0.6 Torr. The majority of the experiments discussed are performed on a Voice100 instrument that has not been described in detail ...
openaire   +2 more sources

Time-integrated thermal desorption for quantitative SIFT-MS analyses of atmospheric monoterpenes

Analytical and Bioanalytical Chemistry, 2019
A new time-integrated thermal desorption technique has been developed that can be used with selected ion flow tube mass spectrometry, TI-TD/SIFT-MS, for off-line quantitative analyses of VOCs accumulated onto sorbents. Using a slow desorption temperature ramp, the absolute amounts of desorbed compounds can be quantified in real time by SIFT-MS and ...
Sovová, K. (Kristýna)   +6 more
openaire   +3 more sources

Increased concentrations of breath haloamines are not detectable in airways inflammation using SIFT-MS

Journal of Breath Research, 2011
The haloamines, including the chloramines (H(2)NCl, HNCl(2)) and bromamine (H(2)NBr), are diffusible gases that are likely to be produced during inflammation and so may be present as markers of lung inflammation on breath. Although haloamines are quite reactive, it is possible to measure these compounds in humid samples using SIFT-MS.
Malina K, Storer   +4 more
openaire   +2 more sources

SIFT-MS Data Analysis

SIFT-MS utilises direct, soft chemical ionisation coupled with mass spectrometric detection, rather than chromatographic separation, to analyse samples with high specificity. This means that SIFT-MS data differ significantly from GC and LC data in that they are a superposition of mass spectra of the different reactive compounds (analytes and matrix ...
openaire   +1 more source

The Principles of the SIFT-MS Technique

The selected ion flow tube mass spectrometry (SIFT-MS) technique operates on very different principles to the more established chromatographic methods. This chapter provides a comprehensive introduction to how SIFT-MS instruments work, the ion–molecule reaction (IMR) chemistry that provides both comprehensive and specific analysis, and the utilisation ...
openaire   +1 more source

SIFT-MS Measurement of VOC Distribution Coefficients in Human Blood Constituents and Urine

Applied Occupational and Environmental Hygiene, 2003
The new technique of selected ion flow tube-mass spectrometry (SIFT-MS) has been applied to the measurement of Henry's Law constants for the volatile organic chemicals o-xylene and trichloroethylene that both have low solubility in aqueous solvents. The method is validated by measurements in water at 298 K using the equilibrium partitioning in closed ...
Paul F, Wilson   +4 more
openaire   +2 more sources

Design and Implementation of Analytical Mathematics for SIFT-MS Medical Applications

2009
Selected Ion Flow Tube-Mass spectrometry (SIFT-MS) is an analytical measurement technology for the real-time quantification of volatile organic compounds in gaseous samples. This technology has current and potential applications in a wide variety of industries, although the focus of this research is in medical science.
openaire   +2 more sources

Application of similarity coefficients to SIFT-MS data for livestock emission characterization

Biosystems Engineering, 2013
Animal farming emissions from pig and broiler chicken livestock activities were analyzed by means of selected ion flow tube mass spectrometry (SIFT-MS) using full mass scans in the m/z range 15–250 with H3O+, NO+ and O2+ as precursor ions. The generated set of data was used to investigate the similarity between samples using raw experimental SIFT-MS ...
Philippe M. Heynderickx   +3 more
openaire   +1 more source

Integrity of Storage Media for Clinical Applications with SIFT-MS Instruments

2006
Tedlar™ bags are a promising medium for remote breath collection and later analysis using SIFT-MS for disease diagnosis. It is important to understand the changes in integrity of samples stored in Tedlar™ bags. However, there is little work into this problem completed to date, and thus little known about these issues.
openaire   +2 more sources