Results 261 to 270 of about 9,530 (292)
Some of the next articles are maybe not open access.

Assessing SIFT-MS Method Feasibility (Procedure 1)

The marked difference in the analytical approach of SIFT-MS compared with the conventional GC and LC techniques means that the feasibility of method transfer – or new method development – for SIFT-MS should be evaluated prior to experimental work. Drawing on principles discussed in Part 1 of this book, this chapter describes a procedure by which the ...
openaire   +1 more source

The Principles of the SIFT-MS Technique

The selected ion flow tube mass spectrometry (SIFT-MS) technique operates on very different principles to the more established chromatographic methods. This chapter provides a comprehensive introduction to how SIFT-MS instruments work, the ion–molecule reaction (IMR) chemistry that provides both comprehensive and specific analysis, and the utilisation ...
openaire   +1 more source

Modifying an Existing SIFT-MS Method (Procedure 7)

SIFT-MS, with its chromatography-free, soft chemical ionisation approach to the analysis of volatile compounds requires different procedures for modifying validated test methods compared to GC. This chapter provides procedures for modifying SIFT-MS methods involving addition or removal of analytes, modification to product ion selections, a change of ...
openaire   +1 more source

Design and Implementation of Analytical Mathematics for SIFT-MS Medical Applications

2009
Selected Ion Flow Tube-Mass spectrometry (SIFT-MS) is an analytical measurement technology for the real-time quantification of volatile organic compounds in gaseous samples. This technology has current and potential applications in a wide variety of industries, although the focus of this research is in medical science.
openaire   +2 more sources

Integrity of Storage Media for Clinical Applications with SIFT-MS Instruments

2006
Tedlar™ bags are a promising medium for remote breath collection and later analysis using SIFT-MS for disease diagnosis. It is important to understand the changes in integrity of samples stored in Tedlar™ bags. However, there is little work into this problem completed to date, and thus little known about these issues.
openaire   +2 more sources

Preparing the Automated SIFT-MS Instrument for Analysis (Procedure 2)

Selected ion flow tube mass spectrometry (SIFT-MS) instruments have different operational procedures compared to conventional chromatographic instruments, since they are based on different principles. This chapter describes, in a general manner, how to prepare a SIFT-MS instrument for analysis, together with a coupled robotic autosampler. Additionally,
openaire   +1 more source

Validating SIFT-MS Analysis of Volatiles in Breath

Current Analytical Chemistry, 2013
Malina Storer   +3 more
openaire   +1 more source

Hmotnostní spektrometrie v proudové trubici s vybranými ionty, SIFT-MS

2013
4 Abstract This thesis describes research that has been carried out during the years 2009-2013 as a part of my PhD project related to the method of selected ion flow tube mass spectrometry (SIFT- MS) and its application in interdisciplinary areas of research.
openaire   +4 more sources

SIFT missense predictions for genomes

Nature Protocols, 2015
Robert Vaser   +2 more
exaly  

SIFT: predicting amino acid changes that affect protein function

Nucleic Acids Research, 2003
Steven Henikoff
exaly  

Home - About - Disclaimer - Privacy