BASIC32: A New ASIC for Silicon Photomultiplier Detectors

open access: yes, 2014
Silicon Photomultipliers (SiPM) have shown to be excellent substitutes for more traditional and bulky Photomultiplier Tubes (PMT) in many photon detection applications, thanks essentially to their high quantum efficiency, low bias voltage and immunity to magnetic fields.
Fabio Ciciriello   +6 more
openaire   +1 more source

Silicon-photomultiplier-based PET/CT reduces the minimum detectable activity of iodine-124. [PDF]

open access: yesSci Rep, 2021
Kersting D   +11 more
europepmc   +1 more source

Enhanced high-sensitivity multi-layer neutron detector based on LiF:ZnS(Ag) scintillator

open access: yesScientific Reports
This study proposes a novel, highly sensitive neutron detector design utilizing a unique multi-layered configuration. Each layer consists of a LiF: ZnS(Ag) scintillator coupled with a transparent neutron moderator that also functions as a light guide for
Ilan Cohen Zada   +2 more
doaj   +1 more source

Silicon photomultipliers in particle and nuclear physics

open access: yesNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2019
17 pages, 18 figures, review paper published in Nuclear Instruments and Methods A; v2 correcting a missing figure link in ...
openaire   +4 more sources

Influence of illumination angle on the output parameters of a silicon photomultiplier

open access: yesВесці Нацыянальнай акадэміі навук Беларусі: Серыя фізіка-тэхнічных навук
The influence of supply voltage on the photosignal value and signal-to-noise ratio has been studied while changing the incidence angle of optical radiation on the photosensitive surface of Ketek PM 3325, ON Semi FC 30035, and KOF5-1035 silicon ...
I. R. Gulakov   +2 more
doaj   +1 more source

Study of Silicon Photomultipliers for the GRIPS Calorimeter Module

open access: yesActa Polytechnica, 2013
GRIPS is a proposed gamma-ray (200 keV to 80 MeV) astronomy mission, which incorporates a pair-creation and Compton scattering telescope, along with X-ray and infrared telescopes.
Alexei Ulyanov   +3 more
doaj  

Performance of a Gamma Detection Unit with Likelihood-Based Localization Method

open access: yesCurrent Directions in Biomedical Engineering
In this paper a new gamma detector for combination with ultrasound imaging to localize radioactively marked lymph nodes is presented. The detector consists of six silicon photomultiplier diodes arranged around a rectangle, to fit an ultrasound device in ...