Results 21 to 30 of about 4,853 (175)

Ultrahigh-speed point scanning two-photon microscopy using high dynamic range silicon photomultipliers

open access: yesScientific Reports, 2021
Conventional two-photon microscopes use photomultiplier tubes, which enable high sensitivity but can detect relatively few photons per second, forcing longer pixel integration times and limiting maximum imaging rates.
Vincent D. Ching-Roa   +4 more
doaj   +1 more source

Liquid Argon Instrumentation and Monitoring in LEGEND-200 [PDF]

open access: yesEPJ Web of Conferences, 2021
LEGEND is the next-generation experiment searching for the neutrinoless double beta decay in 76Ge. The first stage, LEGEND-200, takes over the cryogenic infrastructure of GERDA at LNGS: an instrumented water tank surrounding a 64 m3 liquid argon cryostat.
Schwarz Mario   +11 more
doaj   +1 more source

Simulation of Silicon Photomultipliers [PDF]

open access: yesProceedings of International Workshop on New Photon-detectors — PoS(PhotoDet 2012), 2013
We present a software framework for the simulation of Silicon Photomultipliers (SiPM). The simulation provides a detailed model of the SiPM response to arbitrary light pulses, depending on the basic SiPM characteristics which have to be determined by measurements.
Eckert, P   +2 more
openaire   +2 more sources

Self-heating effect in Silicon-Photomultipliers

open access: yesNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2022
The main effect of radiation damage in a Silicon-Photolumtiplier (SiPM) is a dramatic increase in the dark current. The power dissipated, if not properly cooled, heats the SiPM, whose performance parameters depend on temperature. Heating studies were performed with a KETEK SiPM, glued on an Al$_2$O$_3$ substrate, which is either directly connected to ...
E. Garutti   +5 more
openaire   +2 more sources

Back-Side Readout Silicon Photomultiplier. [PDF]

open access: yesIEEE Trans Electron Devices, 2012
We present a novel structure for the back-side readout silicon photomultipler (SiPM). Current SiPMs are front-illuminated structures with front-side readout, which have relatively small geometric fill factor leading to degradation in their photon detection efficiency (PDE). Back-side readout devices will provide an advantageous solution to achieve high
Choong WS, Holland SE.
europepmc   +4 more sources

Characterization of New-Generation Silicon Photomultipliers for Nuclear Security Applications

open access: yesEPJ Web of Conferences, 2018
Silicon photomultipliers have received a great deal of interest recently for use in applications spanning a wide variety of fields, including nuclear safeguards and nonproliferation.
Wonders Marc A.   +2 more
doaj   +1 more source

Performance Estimation and Selection Guideline of SiPM Chip within SiPM-Based OFDM-OWC System

open access: yesPhotonics, 2022
The orthogonal frequency division multiplexing (OFDM), which has high spectral efficiency, is an attractive solution for silicon photomultiplier (SiPM)-based optical wireless communication (OWC) systems to boost data rates.
Long Zhang   +5 more
doaj   +1 more source

Photon-number statistics with silicon photomultipliers [PDF]

open access: yesJournal of the Optical Society of America B, 2010
We present a description of the operation of a multi-pixel detector in the presence of non-negligible dark-count and cross-talk effects. We apply the model to devise self-consistent calibration strategies to be performed on the very light under investigation.
Marco Ramilli   +5 more
openaire   +3 more sources

Gamma spectrometry with CsI(Tl), NaI(Tl) and CdWO4 scintillation crystals using a silicon photomultiplier [PDF]

open access: yesЯдерна фізика та енергетика
This study investigated using of silicon photomultiplier (SiPM) for scintillation γ-spectrometry with CdWO4, CsI(Tl), and NaI(Tl) crystal scintillators. At room temperature, CsI(Tl) crystal scintillator provides the best performance, while the achievable
R. Yu. Chaplynskyi   +8 more
doaj   +1 more source

Investigation of GaGG:Ce with TOFPET2 ASIC Readout for Applications in Gamma Imaging Systems

open access: yesCrystals, 2020
We investigated two detector modules, each consisting of a 8 × 8 matrix of GaGG:Ce crystals with a crystal size of 3 × 3 × 20 mm3 and a 3.2 mm pitch.
Mihael Makek   +3 more
doaj   +1 more source