Results 11 to 20 of about 72 (72)

Energy-saving hydraulic drive with voltage inverter-fed induction motor

open access: yes, 2010
Analizowano problemy modelowania matematycznego i sterowania natężeniem przepływu i ciśnieniem hydraulicznej stacji zasilającej, której pompę o stałej wydajności napędza silnik indukcyjny. Silnik jest zasilany z falownika napięcia. W układzie zastosowano
Zawarczyński, Ł., Stefański, T.
core  

Computer simulation as an instrument for determining the energy consumption of vehicles with electric drive

open access: yes, 2017
The paper presents the results of measurements and simulation research of a city bus with electric drive. Elaborated model of electric drive uses a submodel of vehicle kinematics, which allows to reproduce the actual conditions of its performance ...
Kołodyńska, A., Litwin, M.
core  

Parameter identification of the mathematical model hydraulic system with inverter drive pump

open access: yes, 2015
W pracy przedstawiono problem modelowania matematycznego i identyfikacji parametrycznej układu hydraulicznego sterowanego objętościowo, którego pompę zębatą napędza silnik indukcyjny (AC) zasilany z falownika.
Zawarczyński, Ł., Stefański, T.
core  

Badanie wpływu zakłóceń sygnałów wejściowych regulatorów typu PI w układzie sterowania polowo-zorientowanego z silnikiem indukcyjnym

open access: yes, 2015
W artykule omówiono wpływ jakościowy zakłóceń działających na sygnały wejściowe poszczególnych regulatorów w układzie polowo-zorientowanym, w którym obiektem sterowania prędkością obrotową jest silnik indukcyjny.
Hudy, W., Jaracz, K.
core  

Estymacja prędkości z wykorzystaniem charakterystyki częstotliwościowej silnika indukcyjnego w warunkach odkształconego napięcia zasilającego

open access: yes, 2015
The analysis of an impact of higher harmonics in induction motor supply voltages on the correctness of an angular speed estimation process, which operation algorithm is based on the knowledge of a motor inductance frequency characteristic is presented in
Kapłon, A., Utrata, G., Rolek, J.
core  

Slip-ring asynchronous motor synchronized with permanent magnets

open access: yes, 2017
A slip-ring asynchronous motor with permanent magnets built into the rotor yoke (SAS PM) is distinguished by the smooth start-up process. After start-up, motor self-synchronizes and operates as synchronous motor excited by magnetic field of permanent ...
Barański, M.   +5 more
core  

Stanowisko do badania możliwości wykorzystania hamulca magnetoreologicznego w układzie regulacji predkosci obrotowej silnika indukcyjnego

open access: yes, 2003
The paper presents the facility which was developed for testing velocity control system with inducation motor and magnetorheological (MR) brake. The induction motor was equipped with frequency inverter. An incremental encoder was used to measure rotation
Bydoń, S.
core  

Układ sterowania przemiennika częstotliwości z falownikiem prądu zasilającego silnik indukcyjny opis patentowy nr 199627 /

open access: yes, 2009
Zgłoszono 4 czerwca 2004 r.Zgłoszenie ogłoszono 12 grudnia 2005 BUP 25/05.O udzieleniu patentu ogłoszono 31 paździenika 2008 WUP 10/08.Nr zgłosz. P 368392.Tyt.
Dziadecki, Aleksander
core  

Układ sterowania przemiennika częstotliwości z falownikiem prądu zasilającego silnik indukcyjny opis patentowy nr 199627

open access: yes, 2008
Zgłoszono 4 czerwca 2004 r.Zgłoszenie ogłoszono 12 grudnia 2005 BUP 25/05.Nr zgłosz.
Dziadecki, Aleksander   +3 more
core  

Operation of an induction motor supplied by voltage with interharmonics

open access: yes, 2018
W artykule omówiono skutki obecności interharmonicznych, tj. częstotliwości wyższych od częstotliwości podstawowej harmonicznej, niebędących jej całkowitą krotnością, w napięciu zasilającym silnik indukcyjny.
Drabek, T.
core   +1 more source

Home - About - Disclaimer - Privacy